| Parameter | Value |
|---|---|
| When communication unitis connected | |
| Item | Specifications |
| Cable | 0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong |
| Details | Slave unit / Wire-saving type |
| Product | Controller |
| Material | Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
| Net weight | 60 g approx. |
| Part Number | HG-TC113 |
| 1 to 7 units | 1 to 6 units |
| Product name | Thru-beam Type Digital Displacement Sensor HG-T |
| 8 to 15 units | 7 to 14 units |
| Display range | -199.999 to 199.999 mm-7.874 to 7.874 in |
| Sampling rate | 1 ms (standard sampling) / 0.5 ms (high-speed sampling) |
| Product Number | HG-TC113 |
| Supply voltage | 24 V DC ±10 %, including ripple 0.5 V (P-P) |
| Pollution degree | 2 |
| Display resolution | 1 μm0.039 mil |
| Operating altitude | 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Current consumption | 100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output. |
| Regulatory compliance | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Applicable sensor head | HG-T1010、HG-T1110 |
| Average count (response time) | 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| Number of connected slave units | Maximum sink current and sourcecurrent of control output |
| Environmental resistance : Protection | IP40(IEC) |
| Maximum number of connectable controllers | Up to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
| Environmental resistance : Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Environmental resistance : Shock resistance | 98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each |
| Environmental resistance : Ambient temperature | -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| Environmental resistance : Vibration resistance | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each |
| Environmental resistance : Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Environmental resistance : Voltage withstandability | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
Technical specifications and performance data
Installation and operation guide