Key Specifications
:When communication unitis connected
Item:Specifications
Cable:0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong
Details:Master unit / High performance type
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
When communication unitis connected
ItemSpecifications
Cable0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong
DetailsMaster unit / High performance type
ProductController
MaterialCase: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight140 g approx.
Part NumberHG-TC101
1 to 7 units1 to 6 units
Product nameThru-beam Type Digital Displacement Sensor HG-T
8 to 15 units7 to 14 units
Display range-199.999 to 199.999 mm-7.874 to 7.874 in
Sampling rate1 ms (standard sampling) / 0.5 ms (high-speed sampling)
Product NumberHG-TC101
Supply voltage24 V DC ±10 %, including ripple 0.5 V (P-P)
Pollution degree2
Display resolution1 μm0.039 mil
Operating altitude2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Current consumption100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output.
Regulatory complianceCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Applicable sensor headHG-T1010、HG-T1110
External input switchingInput 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop".
External output switchingOutput 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2.
Average count (response time)1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Number of connected slave unitsMaximum sink current and sourcecurrent of control output
Interference prevention functionIncorporated(Note) : This function operates for each set of 4 connected controllers.
Environmental resistance : ProtectionIP40(IEC)
Analogue output : Analog current output•Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Analogue output : Analog voltage output•Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
External input(Input 1, Input 2, Input 3)Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx.
Maximum number of connectable controllersUp to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
Environmental resistance : Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Environmental resistance : Shock resistance98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each
Control output(Output 1, Output 2, Output 3)NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Environmental resistance : Ambient temperature-10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Environmental resistance : Vibration resistance10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each
Environmental resistance : Insulation resistance20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Environmental resistance : Voltage withstandability1,000 V AC for one minute between all supply terminals connected together and enclosure
External input(Input 1, Input 2, Input 3) : Input time• Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Control output(Output 1, Output 2, Output 3) : Alarm outputOpen when alarm occurs
Control output(Output 1, Output 2, Output 3) : Judgment outputN.O. / N.C. switching type
Control output(Output 1, Output 2, Output 3) : Short-circuit protectionIncorporated (automatic reset type)

Product Description