Key Specifications
Item:Specifications
Remark:Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃+68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
Stroke:10.5 mm0.413 inor more(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Weight:Net weight: 80 g approx.
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
RemarkWhere measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃+68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
Stroke10.5 mm0.413 inor more(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
WeightNet weight: 80 g approx.
DetailsAir-driven type10 mm0.394 intype General purpose
ProductContact-Type Digital Displacement Sensor
MaterialBody: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM(Note) : The probe is also available as an option.
AccessorySensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc.
Resolution0.5 μm0.02 mil
Part NumberHG-S1010-AC
Product nameContact-Type Digital Displacement Sensor HG-S
Usable fluidClean air (Dew point temperature: -10 ℃+14 ℉or less)
Sampling rate1 ms
Product NumberHG-S1010-AC
Applicable tubeOutside diameter: ø4 mmø0.157 in/ Inside diameter: ø2.5 mmø0.098 in
Measuring force・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type.・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials.
Measuring range10 mm0.394 in(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Grounding methodCapacitor grounding
Pollution degree2
Hot swap functionIncorporated
Operating altitude2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Operation indicatorEquipped (2-color LED: Orange / Green)
Tip deviation amount35 μm1.378 mil(typical value)
Applicable controllerHG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113(Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019.
Insulation resistance100 MΩ or more at 250 V DC
Regulatory complianceCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Working pressure range0.14 to 0.16 MPaWith no seal cap mounted : 0.035 to 0.045 MPa
Indication accuracy(P-P)Full range: 2.0 μm0.079 milor lessLimited range: 1.0 μm0.039 milor less(any 60 μm2.362 mil)
Position detection methodOptical absolute linear encoder method
Capacity to resist pressure0.2 MPa
Environmental resistance : ProtectionIP67 (IEC)With no seal cap mounted : -(Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed.
Environmental resistance : Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Environmental resistance : Shock resistance1,960 m/s2acceleration in X, Y, and Z directions three times each
Environmental resistance : Ambient temperature-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed),Storage: -20 to +60 ℃-4 to +140 ℉
Environmental resistance : Vibration resistance10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each

Product Description

HG-S - Contact measurement sensor. Sensor head with pneumatic actuator. Resolution 0.5μm. Precision 2μm. Range 10mm
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty