| Parameter | Value |
|---|---|
| Item | Specifications |
| Cable | 5-core composite cable, 2 m6.5617 ftlong |
| Weight | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) |
| Details | Measurement center 100mm 3.937 in type |
| Product | CMOS type Micro Laser Distance Sensor |
| Material | Enclosure: Aluminum die-castFront cover: Acrylic |
| Linearity | ±0.1%F.S. |
| Protection | IP67 (IEC) |
| Part Number | HG-C1100 |
| Light source | Red semiconductor laser Class 2 (IEC / EN/ JIS / GB / KS / FDA) / Class II (FDA)(Note)Max. output: 1mWemission peak wavelength: 655nm 0.026 mil(Note) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
| Product name | CMOS type Micro Laser Distance Sensor HG-C |
| Beam diameter | ø120 μm4.7241 milapprox.(Note) This is the size in the measurement center distance. These values were defined by using 1 / e2(13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. |
| Repeatability | 70 μm2.756 mil |
| Response time | Switchable between 1.5 ms / 5 ms / 10 ms |
| Control output | NPN open-collector transistor- Maximum sink current: 50mA- Applied voltage: 30V DC or less (Between control output to 0V)- Residual voltage: 1.5V or less (At 50mA sink current)- Leakage current: 0.1 mA or less |
| External input | NPN non-contact input- Input conditionsInvalid: +8 to +V DC or OpenValid: 0 to +1.2V DC- Input impedance: 10kΩ approx. |
| Product Number | HG-C1100 |
| Supply voltage | 12 to 24V DCplus or minus 10% Ripple P-P 10% |
| Cable extension | Extension up to total 10 m393.701 ftis possible with 0.3 mm2, or more, cable. |
| Measuring range | ±35mm1.328 in |
| Ambient humidity | 35 to 85% RH, Storage: 35 to 85% RH |
| Pollution degree | 2 |
| Shock resistance | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Operating altitude | 2,000 m6561.680 ftor less |
| Ambient illuminance | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Ambient temperature | -10 to +45 ℃-14 to 113 ℉(No dew condensation or icing allowed), Storage: -20 to +60 ℃-4 to 140 ℉ |
| Current consumption | 40 mA or less (at 24V DC supply voltage)65 mA or less (at 12V DC supply voltage)Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) |
| Vibration resistance | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Measurement center distance | 100mm3.937 in |
| Temprerature characteristics | 0.03% F.S. /℃ |
| Control output:Output operation | Either Light-ON or Dark-ON |
| Analogue output : Analog current output | • Output range: 4 to 20mA (at alarm: 0mA)• Output impedance: 300Ω or lessNote : Analog current output has been added from shipment in August 2016. |
| Analogue output : Analog voltage output | • Output range: 0 to 5 V (at alarm: +5.2 V)• Output impedance: 100Ω |
| Control output:Short-circuit protection | Incorporated (Auto reset type) |
| Applicable regulations and certifications | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification(Note) : The UL/c-UL certified products have been shipped since April, 2017. |
Technical specifications and performance data
Installation and operation guide