| Parameter | Value |
|---|---|
| Item | Specifications |
| Output | PNP open-collector transistor- Maximum source current: 50 mA |
| Details | Convergent reflective type |
| Product | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessory | MS-EXL2-3 (Mounting plate): 1 pc. |
| Hysteresis | 20 % or less of operation distance |
| Protection | IP67(IEC) |
| Part Number | EX-L262-P-J |
| Product name | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Repeatability | Perpendicular to sensing axis: 0.2 mm0.0080 inor less |
| Response time | 0.5 ms or less |
| Sensing range | 20 to 70 mm0.787 to 2.756 in(Convergent point: 22 mm0.866 in)(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Product Number | EX-L262-P-J |
| Sensing object | Opaque, translucent or transparent object(Note)Make sure to confirm detection with an actual sensor before use. |
| Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Ambient humidity | 35 to 85%RH , Storage: 35 to 85%RH |
| Emitting element | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS)(Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).)(Maximum output: 1.3 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Ambient temperature | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Current consumption | 15 mA or less |
| Sensitivity adjuster | Continuously variable adjuster |
| Regulatory compliance | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Output:Output operation | Light-ON / Dark-ON selectable by the output operation switching input |
| Emission spot size (Typical) | Approx. 5 × 1 mm0.197 × 0.039 in(vertical x horizontal)(at a sensing distance of 50 mm) |
| Output:Short-circuit protection | Incorporated (short-circuit protection / inverse polarity protection) |
| Minimum sensing object (Typical) | - |
Technical specifications and performance data