| Parameter | Value |
|---|---|
| Item | Specifications |
| Cable | 0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong |
| Output | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 26.4 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) |
| Details | Thru-beam type |
| Product | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessory | MS-EXL2-2 (Mounting plate): 2 pcs. |
| Protection | IP67 (IEC) |
| Part Number | EX-L211-P-C5 |
| Product name | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Repeatability | Perpendicular to sensing axis: 0.05 mm0.0020 inor less |
| Response time | 0.5 ms or less |
| Sensing range | 1 m3.281 ft |
| Product Number | EX-L211-P-C5 |
| Sensing object | Opaque object of ø2 mmø0.079 inor more |
| Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Cable extension | Extension up to total 50 m164.042 ftis possible with 0.3 mm2, or more, cable (thru-beam type: Total 100 m328.084 ftboth emitter and receiver). |
| Power indicator | Green LED (lights up when the power is ON) (incorporated on the emitter) |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitting element | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 1 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Shock resistance | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
| Ambient temperature | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Current consumption | Emitter: 10 mA or lessReceiver: 10 mA or less |
| Operation indicator | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) |
| Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) |
| Sensitivity adjuster | Continuously variable adjuster (incorporated on the receiver) |
| Vibration resistance | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Regulatory compliance | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Output:Output operation | Light-ON / Dark-ON selectable by the output operation switching input |
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Emission spot size (Typical) | Approx. 6 × 4 mm0.236 × 0.157 in(vertical × horizontal)(at a sensing distance of 1 m) |
| Output:Short-circuit protection | Incorporated (short-circuit protection / inverse polarity protection) |
| Minimum sensing object (Typical) | Opaque object of ø0.3 mmø0.012 in(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
| Repeatability (Typical)(perpendicular to sensing axis) | 0.01 mm0.0004 inor less(all area)(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
Technical specifications and performance data