| Parameter | Value |
|---|---|
| Item | Specifications |
| Weight | Net weight : 780 g approx. |
| Details | Head |
| Product | Pulse AC Method Area Ionizer |
| Material | Main unit enclosure: PPS, Stainless steal (SUS)Head mounting bracket: Stainless steal (SUS), Discharge needle: Tungsten |
| Ion balance | plus or minus 30 V or less(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)(Note: Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than plus or minus 10 degrees ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.) |
| Part Number | ER-X064 |
| Product name | Pulse AC Method Area Ionizer ER-X |
| Product Number | ER-X064 |
| Ambient humidity | 35 to 65 % RH, Storage: 35 to 85 % RH |
| Applicable fluid | Air (dried clean air)(Note:The dried clean air is dried (dew point: equivalent of -20 ℃) and filtered (mesh-size: equivalent of 0.01 micro m) air.) |
| Discharge method | Pulse AC method |
| Ozone generation | 0.01 ppm or less |
| Shock resistance | 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each |
| Enclosure earthing | Floating |
| Operating altitude | 2,000 m6561.68 ftor less(Note:Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.) |
| Ambient temperature | 0 to +50 °C +32 to +122 °F (No dew condensation), Storage: -10 to +65 °C +14 to +149 °F |
| Charge removal time | 1 second or less(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
| Discharge frequency | 100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz(Note: The high-voltage cable is also available in lengths of 1 m3.281 ftand 2 m6.562 ft. The discharge frequency of 1 m3.281 ft/ 2 m6.562 ftcables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.) |
| Maximum air pressure | 0.5 Mpa |
| Vibration resistance | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), TÜV SÜD certification (USA, Canada) |
| Discharge output voltage | ±7,000 V approx. |
| Length of high-voltage cable | 0.5 m1.640 ft(Note:The high-voltage cable is also available in lengths of 1 m3.281 ftand 2 m6.562 ft. The discharge frequency of 1 m3.281 ft/ 2 m6.562 ftcables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.) |
| Effective charge removal width | 640 mm 25.197 in approx. |
Technical specifications and performance data
Installation and operation guide