| Parameter | Value |
|---|---|
| DIN EN 62208 (VDE 0660-511):2012-06 (in parts) | |
| Type | high |
| Color | flame red (RAL 3000) |
| Pitch | 7.62 mm |
| Width | 7 mm |
| Cycles | 2 |
| Height | 4.76 mm |
| Length | 10.5 mm |
| Result | Test passed |
| General | Can be labeled via thermal transfer |
| IRM 901 | Test passed |
| IRM 902 | Test passed |
| Material | PC |
| Procedure | Method B |
| Components | free from silicone and halogen |
| Shelf life | 2 years |
| Product type | Labeled terminal marker |
| Requirements | ≥ 5 N |
| Mounting type | snap into tall marker groove |
| Specification | EN ISO 1518-1:2023 (following) |
| Test duration | 96 h |
| Wipe resistance | DIN EN 61010-1 (VDE 0411-1) |
| Article revision | 02 |
| Identification technology | Thermal transfer for sheets and cards |
| Diesel[CAS No. 68476-34-6] | Test passed |
| Isopropyl[CAS No. 67-63-0] | Test passed |
| Rating 100 °C (121 °C) | Test passed |
| n-Hexane[CAS No. 110-54-3] | Test passed |
| Number of individual labels | 48 |
| Ambient temperature (operation) | -40 °C ... 100 °C |
| Number of individual labels per row | 8 |
| Flammability rating according to UL 94 | V0 |
| Recommended humidity (storage/transport) | 50 % (Storage in a dry and dark place in the original packaging is recommended) |
| Water + Petroleum ether[CAS No. 64742-82-1] | Test passed |
| Sodium hydroxide 0.1 mol/l[CAS No. 1310-73-2] | Test passed |
| Recommended ambient temperature (storage/transport) | 23 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Technical specifications and performance data