| Parameter | Value |
|---|---|
| Mounting of PCB on corner feeder: 0.4 Nm-0.5 Nm / 500 rpm-1000 rpm | |
| Type | Housing half-shell is prepared to accommodate a heatsink |
| Color | light grey (7035) |
| Depth | 21.75 mm |
| Force | 20 N |
| Width | 125 mm |
| Height | 87 mm |
| Result | Test passed |
| General | Refer to the data sheet for the range in the download area. |
| Amplitude | 0.15 mm (10 Hz ... 58.1 Hz) |
| Frequency | 10 - 150 - 10 Hz |
| Pulse shape | Half-sine |
| Sweep speed | 1 octave/min |
| Temperature | 850 °C |
| Acceleration | 2g (58.1 Hz ... 150 Hz) |
| Housing type | Universal housings |
| Product type | Housing half shells |
| Mounting type | Screw mounting |
| PCB thickness | 0.8 mm ... 3 mm |
| Specification | IEC 60068-2-6:2007-12 |
| Test duration | 1 h |
| Height of fall | 50 cm |
| Housing series | UCS |
| Product family | UCS 125-87 |
| Shock duration | 11 ms |
| Test directions | X-, Y- and Z-axis |
| Housing material | PC |
| Time of exposure | 30 s |
| Cross section AWG | (converted acc. to IEC) |
| Mounting position | any |
| Type of PCB mount | Bolt mounting |
| Type of packaging | Box packaging |
| Dimensional drawing | |
| Insulating material | PC |
| Thickness of the PCB | 0.8 mm ... 3 mm |
| Max. IP code to attain | IP40 |
| Test duration per axis | 2.5 h |
| Surface characteristics | untreated |
| Tightening torque / speed | Screw connection between housing halves: 1.2 Nm-1.4 Nm / 500 rpm-1000 rpm |
| CTI according to IEC 60112 | 225 |
| Ventilation openings present | no |
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Number of shocks per direction | 3 |
| Ambient temperature (operation) | -40 °C ... 105 °C (depending on power dissipation) |
| Relative humidity (storage/transport) | 95 % |
| Result, degree of protection, IP code | IP20 |
| Flammability rating according to UL 94 | V0 |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Technical specifications and performance data