| Parameter | Value |
|---|---|
| GTIN | 4055626166575 |
| Orderkey | 2907160 |
| Depth (Note) | 115 mm |
| Packing unit | 1 pc |
| Width (Note) | 60 mm |
| (Input data) | typ. 96 % (Battery operation) |
| Height (Note) | 130 mm |
| (Output data) | > 388314 h (230 V AC, at 60 °C) |
| Country of origin | CN (China) |
| (Charging process) | UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C |
| Custom tariff number | 85044030 |
| Derating (Input data) | > 60 °C (2.5%/K of POutnom.) |
| Efficiency (Input data) | typ. 85 % (120 V AC) |
| Net weight (Output data) | 0.75 kg |
| Shock (Charging process) | 30g, 18 ms according to IEC 60068-2-27 |
| Stripping length (General) | 10 mm |
| Voltage (Charging process) | 10 V (Test Level 3) |
| Climatic class (Dimensions) | 3K3 (in acc. with EN 60721) |
| Comments (Charging process) | Criterion B |
| Connection method (General) | Push-in connection |
| Residual ripple (Input data) | < 20 mV |
| Control deviation (Input data) | < 0.75 % (Static load change 10 % ... 90 %) |
| Protection class (Output data) | I |
| Mounting position (Output data) | horizontal DIN rail NS 35, EN 60715 |
| UL approvals (Charging process) | UL Listed UL 61010 |
| Degree of pollution (Dimensions) | 2 |
| Feedback resistance (Input data) | ≤ 35 V DC |
| Installation height (Dimensions) | ≤ 4000 m (> 2000 m, observe derating) |
| Degree of protection (Dimensions) | IP20 |
| Frequency range (Charging process) | 0.15 MHz ... 80 MHz |
| Assembly instructions (Output data) | alignable: horizontally 0 mm, vertically 50 mm |
| Connection in parallel (Input data) | yes, with diode module uncoupled |
| Nominal output voltage (Input data) | 24 V DC |
| Contact discharge (Charging process) | 4 kV (Test Level 2) |
| Mains buffering (Ambient conditions) | ≥ 15 ms (120 V AC) |
| Weight per Piece (excluding packing) | 943.600 g |
| Depth with alternative assembly (Note) | 60 mm |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Test field strength (Charging process) | 10 V/m (Test Level 3) |
| Width with alternative assembly (Note) | 115 mm |
| Dynamic Boost (IDyn.Boost) (Input data) | 7.5 A |
| Height with alternative assembly (Note) | 130 mm |
| Low Voltage Directive (Charging process) | Conformance with Low Voltage Directive 2014/35/EC |
| MTBF (IEC 61709, SN 29500) (Output data) | > 1395470 h (230 V AC, at 25 °C) |
| Nominal output current (IN) (Input data) | 5 A |
| Standards/regulations (Charging process) | EN 61000-4-12 |
| Vibration (operation) (Charging process) | in accordance with IEC 60068-2-6 |
| Stripping length (Connection data, input) | 10 mm |
| Conductor cross section AWG max. (General) | 12 |
| Conductor cross section AWG min. (General) | 24 |
| Connection method (Connection data, input) | Push-in connection |
| Stripping length (Connection data, output) | 8 mm |
| Typical response time (Ambient conditions) | 60 ms |
| AC input voltage range (Ambient conditions) | 100 V AC ... 240 V AC -15 % ... +10 % |
| Conducted noise emission (Charging process) | EN 61000-6-4 (Class A) |
| Connection method (Connection data, output) | Push-in connection |
| Input fuse, integrated (Ambient conditions) | 6.3 A (slow-blow, internal) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Conductor cross section solid max. (General) | 4 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Standard - Safe isolation (Charging process) | DIN VDE 0100-410 |
| Insulation voltage input/output (Output data) | 3 kV AC (type test) |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Charge current (Connection data for signaling) | 0.2 A ... 1.5 A (-25 °C ... 60 °C) |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Electromagnetic compatibility (Charging process) | Conformance with EMC Directive 2014/30/EU |
| Inrush current limiting/I²t (Ambient conditions) | < 0.43 A2s |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Overvoltage category (EN 61010-1) (Charging process) | II |
| Ambient temperature (start-up type tested) (Dimensions) | -40 °C |
| Setting range of the output voltage (USet) (Input data) | 24 V DC ... 28 V DC (> 24 V constant capacity) |
| Standard – Safety extra-low voltage (Charging process) | IEC 61010 (SELV) / (PELV) |
| Conductor cross section AWG max. (Connection data, input) | 12 |
| Conductor cross section AWG min. (Connection data, input) | 24 |
| Conductor cross section AWG max. (Connection data, output) | 16 |
| Conductor cross section AWG min. (Connection data, output) | 24 |
| Charge characteristic curve (Connection data for signaling) | IU0U |
| Conductor cross section solid max. (Connection data, input) | 4 mm² |
| Conductor cross section solid min. (Connection data, input) | 0.2 mm² |
| Max. permissible relative humidity (operation) (Dimensions) | ≤ 95 % (At +25°C, non-condensing) |
| Maximum power dissipation in no-load condition (Input data) | < 3 W (230 V AC) |
| Conductor cross section solid max. (Connection data, output) | 1.5 mm² |
| Conductor cross section solid min. (Connection data, output) | 0.2 mm² |
| Surge protection against internal surge voltages (Input data) | < 30 V DC |
| Conductor cross section flexible max. (Connection data, input) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, input) | 0.2 mm² |
| Conductor cross section flexible max. (Connection data, output) | 1.5 mm² |
| Conductor cross section flexible min. (Connection data, output) | 0.2 mm² |
| Standard - power supply devices for low voltage with DC output (Charging process) | EN 61204-3 |
Technical specifications and performance data
Installation and operation guide