Service time: Monday to Friday 9:00-18:00
TRIO-UPS-2G/1AC/24DC/10 - TRIO-UPS-2G/1AC/24DC/10 2907161 PHOENIX CONTACT Uninterruptible power supply with integrated power supply un..
In Stock Hot Product

TRIO-UPS-2G/1AC/24DC/10

TRIO-UPS-2G/1AC/24DC/10 2907161 PHOENIX CONTACT Uninterruptible power supply with integrated power supply un..

$0.00USD
4164 in stock
Key Specifications
GTIN:4055626166582
Orderkey:2907161
Packing unit:1 pc
(Input data):typ. 96 % (Battery operation)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626166582
Orderkey2907161
Packing unit1 pc
(Input data)typ. 96 % (Battery operation)
(Output data)> 575978 h (230 V AC, at 60 °C)
Country of originCN (China)
(Charging process)UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C
Custom tariff number85044030
Derating (Input data)> 60 °C (2.5%/K of POutnom.)
Efficiency (Input data)typ. 90 % (120 V AC)
Net weight (Output data)1.34 kg
Shock (Charging process)30g, 18 ms according to IEC 60068-2-27
Stripping length (General)10 mm
Voltage (Charging process)10 V (Test Level 3)
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Comments (Charging process)Criterion B
Connection method (General)Push-in connection
Depth (Key Commercial Data)160 mm
Width (Key Commercial Data)68 mm
Height (Key Commercial Data)130 mm
Residual ripple (Input data)< 20 mV
Control deviation (Input data)< 0.55 % (Static load change 10 % ... 90 %)
Protection class (Output data)I
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
UL approvals (Charging process)UL Listed UL 61010
Degree of pollution (Dimensions)2
Feedback resistance (Input data)≤ 35 V DC
Installation height (Dimensions)≤ 4000 m (> 2000 m, observe derating)
Degree of protection (Dimensions)IP20
Frequency range (Charging process)0.15 MHz ... 80 MHz
Assembly instructions (Output data)alignable: horizontally 0 mm, vertically 50 mm
Connection in parallel (Input data)yes, with diode module uncoupled
Nominal output voltage (Input data)24 V DC
Contact discharge (Charging process)4 kV (Test Level 2)
Mains buffering (Ambient conditions)≥ 25 ms (120 V AC)
Weight per Piece (excluding packing)1,700.000 g
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Test field strength (Charging process)10 V/m (Test Level 3)
Dynamic Boost (IDyn.Boost) (Input data)15 A
Low Voltage Directive (Charging process)Conformance with Low Voltage Directive 2014/35/EC
MTBF (IEC 61709, SN 29500) (Output data)> 2007013 h (230 V AC, at 25 °C)
Nominal output current (IN) (Input data)10 A
Standards/regulations (Charging process)EN 61000-4-12
Vibration (operation) (Charging process)in accordance with IEC 60068-2-6
Stripping length (Connection data, input)10 mm
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Push-in connection
Stripping length (Connection data, output)8 mm
Typical response time (Ambient conditions)200 ms
AC input voltage range (Ambient conditions)100 V AC ... 240 V AC -15 % ... +10 %
Conducted noise emission (Charging process)EN 61000-6-4 (Class A)
Connection method (Connection data, output)Push-in connection
Input fuse, integrated (Ambient conditions)6.3 A (slow-blow, internal)
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)4 mm²
Conductor cross section solid min. (General)0.2 mm²
Standard - Safe isolation (Charging process)DIN VDE 0100-410
Insulation voltage input/output (Output data)4 kV AC (type test)
Charge current (Connection data for signaling)0.2 A ... 3 A (-25 °C ... 60 °C)
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Electromagnetic compatibility (Charging process)Conformance with EMC Directive 2014/30/EU
Inrush current limiting/I²t (Ambient conditions)< 0.2 A2s
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Overvoltage category (EN 61010-1) (Charging process)II
Depth with alternative assembly (Key Commercial Data)68 mm
Width with alternative assembly (Key Commercial Data)160 mm
Height with alternative assembly (Key Commercial Data)130 mm
Ambient temperature (start-up type tested) (Dimensions)-40 °C
Setting range of the output voltage (USet) (Input data)24 V DC ... 28 V DC (> 24 V constant capacity)
Standard – Safety extra-low voltage (Charging process)IEC 61010 (SELV) / (PELV)
Conductor cross section AWG max. (Connection data, input)12
Conductor cross section AWG min. (Connection data, input)24
Conductor cross section AWG max. (Connection data, output)16
Conductor cross section AWG min. (Connection data, output)24
Charge characteristic curve (Connection data for signaling)IU0U
Conductor cross section solid max. (Connection data, input)4 mm²
Conductor cross section solid min. (Connection data, input)0.2 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 93 % (At +25°C, non-condensing)
Maximum power dissipation in no-load condition (Input data)< 3 W (230 V AC)
Conductor cross section solid max. (Connection data, output)1.5 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Surge protection against internal surge voltages (Input data)< 30 V DC
Conductor cross section flexible max. (Connection data, input)2.5 mm²
Conductor cross section flexible min. (Connection data, input)0.2 mm²
Conductor cross section flexible max. (Connection data, output)1.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Standard - power supply devices for low voltage with DC output (Charging process)EN 61204-3

Product Description

TRIO UPS - UPS with integrated power supply for AGM lead energy accumulators 1.2 Ah - 40 Ah, USB (Modbus/RTU), Rail mounting, Push-in connection, input: 1 phase, output: 24 VDC / 10 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top