Service time: Monday to Friday 9:00-18:00
TRIO-UPS-2G/1AC/1AC/230V/750VA - TRIO-UPS-2G/1AC/1AC/230V/750VA 2905909 PHOENIX CONTACT Uninterruptible power supply
In Stock Hot Product

TRIO-UPS-2G/1AC/1AC/230V/750VA

TRIO-UPS-2G/1AC/1AC/230V/750VA 2905909 PHOENIX CONTACT Uninterruptible power supply

$0.00USD
4961 in stock
Key Specifications
GTIN:4055626007502
Orderkey:2905909
Catalog page:Page 282 (C-4-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626007502
Orderkey2905909
Catalog pagePage 282 (C-4-2017)
Packing unit1 pc
(Dimensions)30g in each space direction with UWA 130
(General data)1 min. (600 W)
Country of originDE (Germany)
Shock (Dimensions)20g in all directions (EN 60068-2-27)
Custom tariff number85044030
Capacity (General data)3.4 Ah
Battery fuse (General data)40 A, 32 V
Battery type (General data)2x Panasonic UP-VW1220P1
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Depth (Key Commercial Data)136 mm
Low signal (Remote control)Connection to SGnd with < 2.7 kΩ
Service life (General data)6 Years ... 9 Years (20 °C)
Shock (Device combinations)20g in all directions (EN 60068-2-27)
Width (Key Commercial Data)210 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Buffer period (General data)20 min. (100 W)
Charging time (General data)7 h
Height (Key Commercial Data)170 mm
High signal (Remote control)Open (> 200 kΩ between bat. start and SGnd)
Latest startup (General data)6 Months (0 °C ... 20 °C)
Maximum altitude (Dimensions)≤ 3000 mm (> 2000 m, observe derating)
Stripping length (Input data)10 mm
Voltage (Device combinations)10 V
Comments (Device combinations)Criterion B
Connection method (Input data)Push-in connection
(Output data (mains operation))60 Hz
Degree of pollution (Dimensions)2
Weight (Connection data, output)5.7 kg
Battery technology (General data)Lead rechargeable battery module
Stripping length (Energy storage)15 mm
Connection method (Energy storage)Push-in connection
Vibration (operation) (Dimensions)5 Hz ... 100 Hz, 0.7g (EN 60068-2-6)
Efficiency (Connection data, output)> 95 % (with charged energy storage device)
Frequency range (Ambient conditions)45 Hz ... 55 Hz
Input fuse (Connection data, output)10 A 400 V gRL
Noise immunity (Device combinations)Noise immunity according to EN 62040-2-2006
Weight per Piece (excluding packing)6,155.600 g
Crest factor (Connection data, input)2.8
Frequency range (Device combinations)0.15 MHz ... 80 MHz
UPS connection in series (Interfaces)no
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 3
Hood version (Connection data, output)PC + ABS
Apparent power (Connection data, input)750 VA
Contact discharge (Device combinations)4 kV (Test Level 2)
UPS connection in parallel (Interfaces)no
Current consumption (Ambient conditions)3 A
Input voltage range (Ambient conditions)184 V AC ... 264 V AC
Nominal output current (IN) (Output data)3 A (750 VA)
Nominal output voltage (UN) (Output data)230 V AC
Switch-over time (Connection data, input)< 10 ms
Test field strength (Device combinations)10 V/m
Type of housing (Connection data, output)Steel sheet, zinc-plated
Low signal (Connection data for signaling)Connection to SGnd with < 2.7 kΩ
Nominal input voltage (Ambient conditions)230 V AC
Protection class (Connection data, output)I
Designation (Connection data for signaling)Remote
High signal (Connection data for signaling)Open (> 35 kΩ between remote and SGnd)
Low Voltage Directive (Device combinations)Conformance with Low Voltage Directive 2014/35/EC
Standards/regulations (Device combinations)EN 61000-4-8
Vibration (operation) (Device combinations)5 Hz ... 100 Hz, 0.7g (EN 60068-2-6)
Ambient temperature (operation) (Dimensions)0 °C ... 40 °C
Permissible backup fuse (Ambient conditions)B6 B10 B16
Conductor cross section AWG max. (Input data)12
Conductor cross section AWG min. (Input data)24
Conducted noise emission (Device combinations)EN 55016 EN 62040-02 (Class C2)
Degree of protection (Connection data, output)IP20
Conductor cross section solid max. (Input data)4 mm²
Conductor cross section solid min. (Input data)0.2 mm²
Interface (Battery-operated start (bat. start))MINI-USB type B
Power factor (cos phi) (Connection data, input)0.8
Conductor cross section AWG max. (Energy storage)8
Conductor cross section AWG min. (Energy storage)24
Rated Power (Real Power) (Connection data, input)600 W
Conductor cross section flexible max. (Input data)2.5 mm²
Conductor cross section flexible min. (Input data)0.2 mm²
Stripping length (Output data (battery operation))10 mm
Conductor cross section solid max. (Energy storage)10 mm²
Conductor cross section solid min. (Energy storage)0.2 mm²
Connection method (Output data (battery operation))Push-in connection
Electromagnetic compatibility (Device combinations)Conformance with EMC Directive 2014/30/EU
Ambient temperature (storage/transport) (Dimensions)-15 °C ... 40 °C (with charged energy storage device)
Can be extended with external battery (General data)1x 24 V 3.4 Ah
MTBF (IEC 61709, SN 29500) (Connection data, output)> 206000 h (40°C)
Conductor cross section flexible max. (Energy storage)6 mm²
Conductor cross section flexible min. (Energy storage)0.2 mm²
Form of output voltage (Output data (mains operation))Pure sine
Output voltage (Connection data for the external battery)24 V (SELV)
Status display (Connection data for the external battery)LED red
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (25 °C, non-condensing)
Nominal output current (IN) (Output data (mains operation))3 A (750 VA)
Nominal output voltage (UN) (Output data (mains operation))230 V AC
Switching output (Connection data for the external battery)Transistor output, active
Classification according to IEC 62040-3 (Connection data, input)VFD-SS-311
Conductor cross section AWG max. (Output data (battery operation))12
Conductor cross section AWG min. (Output data (battery operation))24
Continuous load current (Connection data for the external battery)≤ 20 mA
Conductor cross section solid max. (Output data (battery operation))4 mm²
Conductor cross section solid min. (Output data (battery operation))0.2 mm²
Conductor cross section flexible max. (Output data (battery operation))2.5 mm²
Conductor cross section flexible min. (Output data (battery operation))0.2 mm²
Output voltage (Status and diagnostics indicator / signal outputs - Alarm)24 V (SELV)
Status display (Status and diagnostics indicator / signal outputs - Alarm)Yellow LED
Status display (Status and diagnostics indicator / signal outputs - Ready)Yellow LED
Switching output (Status and diagnostics indicator / signal outputs - Alarm)Transistor output, active
Stripping length (Status and diagnostics indicator /signal outputs - Service)8 mm
Connection method (Status and diagnostics indicator /signal outputs - Service)Push-in connection
Output voltage (Status and diagnostics indicator / signal outputs - Battery Mode)24 V (SELV)
Continuous load current (Status and diagnostics indicator / signal outputs - Alarm)≤ 20 mA
Status display (Status and diagnostics indicator / signal outputs - Battery Charge)Green LED
Switching output (Status and diagnostics indicator / signal outputs - Battery Mode)Transistor output, active
Frequency (after automatic detection in mains operation) (Output data (mains operation))50 Hz
Status display (Status and diagnostics indicator / signal outputs - AC OK, P>Pn, Remote)LED red
Continuous load current (Status and diagnostics indicator / signal outputs - Battery Mode)≤ 20 mA
Conductor cross section AWG max. (Status and diagnostics indicator /signal outputs - Service)16
Conductor cross section AWG min. (Status and diagnostics indicator /signal outputs - Service)24
Conductor cross section solid max. (Status and diagnostics indicator /signal outputs - Service)1.5 mm²
Conductor cross section solid min. (Status and diagnostics indicator /signal outputs - Service)0.2 mm²
Conductor cross section flexible max. (Status and diagnostics indicator /signal outputs - Service)1.5 mm²
Conductor cross section flexible min. (Status and diagnostics indicator /signal outputs - Service)0.2 mm²

Product Description

1 AC/1 AC/750 VA uninterruptible power supply with integrated energy storage, lead-acid AMG, VRLA technology, 24 DC and 4 Ah for 230 V AC applications.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top