Service time: Monday to Friday 9:00-18:00
TRIO-UPS/1AC/24DC/ 5 - TRIO-UPS/1AC/24DC/ 5 2866611 PHOENIX CONTACT Uninterruptible power supply
In Stock Hot Product

TRIO-UPS/1AC/24DC/ 5

TRIO-UPS/1AC/24DC/ 5 2866611 PHOENIX CONTACT Uninterruptible power supply

$0.00USD
3188 in stock
Key Specifications
GTIN:4046356311809
Orderkey:2866611
Catalog page:Page 300 (C-4-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356311809
Orderkey2866611
Catalog pagePage 300 (C-4-2017)
Packing unit1 pc
(Input data)> 86 % (Battery operation)
(Output data)
Country of originCN (China)
(Charging process)15 Hz ... 150 Hz, 2.3g, 90 min.
Custom tariff number85044030
(Ambient conditions)200 ms (120 V AC)
Derating (Input data)55 °C ... 70 °C (2.5%/K)
Screw thread (General)M3
Efficiency (Input data)> 88 % (230 V AC, network operation)
Net weight (Output data)1.1 kg
Shock (Charging process)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Voltage (Charging process)10 V
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Comments (Charging process)Criterion B
Connection method (General)Screw connection
Depth (Key Commercial Data)118 mm
IQ technology (Output data)no
Memory medium (Output data)External, battery 1.3 Ah / 3.4 Ah / 7.2 Ah / 12 Ah
Width (Key Commercial Data)60 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)130 mm
Operating mode (Output data)
Residual ripple (Input data)< 10 mVPP
Control deviation (Input data)< 1 % (change in load, static 10 % ... 90 %)
Protection class (Output data)I
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
UL approvals (Charging process)UL/C-UL listed UL 508
Buffer time (Ambient conditions)adjustable: 0.5 min; 1 min; 2 min; 3 min; 5 min; 10 min; 15 min; 20 min; PC-Mode
Degree of pollution (Dimensions)2
Feedback resistance (Input data)35 V DC
Degree of protection (Dimensions)IP20
Noise emission (Charging process)EN 55011 (EN 55022)
Noise immunity (Charging process)EN 61000-6-2:2005
Output current limit (Input data)max. 6 A (Mains operation)
Frequency range (Charging process)10 kHz ... 80 MHz
Assembly instructions (Output data)alignable: horizontally 0 mm, vertically 50 mm
Connection in parallel (Input data)Yes, 2
Nominal output voltage (Input data)24 V DC
Contact discharge (Charging process)6 kV
Mains buffering (Ambient conditions)see diagram
Rail applications (Charging process)EN 50121-4
Weight per Piece (excluding packing)1,147.000 g
Screw thread (Connection data, input)M3
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
Screw thread (Connection data, output)M3
Test field strength (Charging process)10 V/m
Protective circuit (Ambient conditions)Transient surge protection Varistor
Current consumption (Ambient conditions)1.1 A (230 V AC, maximum)
Low Voltage Directive (Charging process)Conformance with LV directive 2006/95/EC
MTBF (IEC 61709, SN 29500) (Output data)
Nominal output current (IN) (Input data)5 A (-25 °C ... 55 °C)
Shipbuilding approval (Charging process)DNV GL (EMC B)
Standards/regulations (Charging process)EN 61000-4-11
Vibration (operation) (Charging process)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Stripping length (Connection data, input)8 mm
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Screw connection
Typical response time (Ambient conditions)150 ms (230 V AC)
AC input voltage range (Ambient conditions)85 V AC ... 264 V AC (Derating < 90 V AC: 2.5%V)
Input fuse, integrated (Ambient conditions)6.3 A (slow-blow, internal)
Input voltage range DC (Ambient conditions)100 V DC ... 350 V DC (UL508: 100 ... 250 V)
Power factor (cos phi) (Ambient conditions)approx. 0.5
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Standard - Safe isolation (Charging process)DIN VDE 0100-410
Insulation voltage input/output (Output data)4 kV (type test)
Charge current (Connection data for signaling)0.2 A ... 1.5 A (Default 1.0 A)
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Standard - Electrical safety (Charging process)EN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Charging process)Conformance with EMC Directive 2014/30/EU
Nominal input voltage range (Ambient conditions)100 V AC ... 240 V AC
Inrush current limiting/I²t (Ambient conditions)< 1.3 A2s
Peak switching voltages nominal load (Input data)< 25 mVPP
Connection in acc. with standard (Charging process)CUL
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
End-of-charge voltage (Connection data for signaling)25 V DC ... 30 V DC (Default 27.6 V DC)
Setting range of the output voltage (USet) (Input data)22.5 V DC ... 29.5 V DC (Network operation; in the buffer mode, dependent on the battery voltage of 27.9 V DC ... 19.2 V DC)
Quality check of battery (Connection data for signaling)4 h ... 200 h (Default 12 h)
Standard – Safety extra-low voltage (Charging process)EN 60950-1 (SELV)
Temperature compensation (Connection data for signaling)0 mV/K ... 200 mV/K (42 mV/K by default)
Alarm signaling threshold (Connection data for signaling)18 V DC ... 30 V DC (Default 20.4 V DC)
Conductor cross section AWG max. (Connection data, input)12
Conductor cross section AWG min. (Connection data, input)24
Deep discharge protection (Connection data for signaling)18 V DC ... 21 V DC (Default 19.2 V DC)
Conductor cross section AWG max. (Connection data, output)12
Conductor cross section AWG min. (Connection data, output)24
Charge characteristic curve (Connection data for signaling)I/U characteristic curve
Conductor cross section solid max. (Connection data, input)2.5 mm²
Conductor cross section solid min. (Connection data, input)0.2 mm²
Max. permissible relative humidity (operation) (Dimensions)95 % (at 25 °C, non-condensing)
Conductor cross section solid max. (Connection data, output)2.5 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Surge protection against internal surge voltages (Input data)< 35 V DC
Conductor cross section flexible max. (Connection data, input)2.5 mm²
Conductor cross section flexible min. (Connection data, input)0.2 mm²
Conductor cross section flexible max. (Connection data, output)2.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Battery presence check/time interval (Connection data for signaling)60 s
Standard – Limitation of mains harmonic currents (Charging process)EN 61000-3-2
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment (Charging process)EN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Charging process)EN 50178/VDE 0160 (PELV)

Product Description

Uninterruptible power supply with integrated power supply. For AGM lead-acid energy storage MINI-BAT/24/DC/1.3 AH, QUINT-BAT/24DC 3.4 AH... 12 AH rated capacity. Input: single-phase, output: 24 V DC/5
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top