Key Specifications
GTIN:4046356960946
Note:Made to Order (non-returnable)
Orderkey:2903153
Catalog page:Page 222 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356960946
NoteMade to Order (non-returnable)
Orderkey2903153
Catalog pagePage 222 (C-4-2017)
Packing unit1 pc
(Input data)< 0.1 % (change in input voltage ±10 %)
(Output data)> 620000 h (60 °C)
Country of originCN (China)
Custom tariff number85044030
(Ambient conditions)typ. 20 ms (500 V AC)
Derating (Input data)> 60 °C ... 70 °C (2.5%/K)
Efficiency (Output data)> 91 % (at 400 V AC and nominal values)
Net weight (Output data)0.4 kg
Output power (Input data)120 W
Stripping length (General)10 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Push-in connection
Depth (Key Commercial Data)115 mm
Width (Key Commercial Data)35 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)130 mm
Residual ripple (Input data)≤ 20 mVPP
Control deviation (Input data)< 1 % (change in load, static 10 % ... 90 %)
Protection class (Output data)II (in closed control cabinet)
Input fuse (Ambient conditions)3.15 A (internal (device protection), slow-blow)
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
(Connection data for signaling)15 Hz ... 150 Hz, 4g, 90 min.
Degree of pollution (Dimensions)2
Installation height (Dimensions)≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
Connection in series (Input data)yes
Degree of protection (Dimensions)IP20
Degree of protection (Output data)IP20
Typical response time (Input data)< 1 s
Assembly instructions (Output data)alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
Connection in parallel (Input data)Yes, for redundancy and increased capacity
Nominal output voltage (Input data)24 V DC ±1 %
Mains buffering (Ambient conditions)typ. 20 ms (400 V AC)
Weight per Piece (excluding packing)568.500 g
Shock (Connection data for signaling)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
AC frequency range (Ambient conditions)50 Hz ... 60 Hz
Dynamic Boost (IDyn.Boost) (Input data)7.5 A (5 s)
Type of protection (Ambient conditions)Transient surge protection
Voltage (Connection data for signaling)10 V (Test Level 3)
Comments (Connection data for signaling)Criterion B
Current consumption (Ambient conditions)3x 0.4 A (400 V AC)
Input voltage range (Ambient conditions)3x 400 V AC ... 500 V AC -20 % ....+15 %
MTBF (IEC 61709, SN 29500) (Output data)> 2300000 h (25 °C)
Nominal output current (IN) (Input data)5 A
Inrush surge current (Ambient conditions)≤ 22 A (typical)
Power loss nominal load max. (Input data)< 12 W (480 V AC)
Stripping length (Connection data, input)10 mm
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Push-in connection
Output overvoltage protection (Input data)≤ 30 V DC
Stripping length (Connection data, output)8 mm
Connection method (Connection data, output)Push-in connection
Power factor (cos phi) (Ambient conditions)0.55
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)4 mm²
Conductor cross section solid min. (General)0.2 mm²
Discharge current to PE (Ambient conditions)< 0.25 mA
UL approvals (Connection data for signaling)UL Listed UL 508
Insulation voltage input/output (Output data)3 kV AC (type test)
Noise emission (Connection data for signaling)EN 55011 (EN 55022)
Noise immunity (Connection data for signaling)Immunity according to EN 61000-6-2 (industrial)
Nominal power consumption (Ambient conditions)243.6 VA
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Frequency range (Connection data for signaling)0.15 MHz ... 80 MHz
Nominal input voltage range (Ambient conditions)3x 400 V AC ... 500 V AC
Contact discharge (Connection data for signaling)4 kV (Test Level 2)
Protective circuit/component (Ambient conditions)Varistor
Rail applications (Connection data for signaling)EN 50121-4
Test field strength (Connection data for signaling)3 V/m (Test Level 2)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Low Voltage Directive (Connection data for signaling)Conformance with Low Voltage Directive 2014/35/EC
Standards/regulations (Connection data for signaling)EN 61000-6-3
Vibration (operation) (Connection data for signaling)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Setting range of the output voltage (USet) (Input data)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Choice of suitable circuit breakers (Ambient conditions)6 A ... 16 A (Characteristics B, C, D, K)
Conducted noise emission (Connection data for signaling)EN 55016 EN 61000-6-4 (Class A)
Conductor cross section AWG max. (Connection data, input)12
Conductor cross section AWG min. (Connection data, input)24
Standard - Safe isolation (Connection data for signaling)DIN VDE 0100-410
Conductor cross section AWG max. (Connection data, output)16
Conductor cross section AWG min. (Connection data, output)24
Conductor cross section solid max. (Connection data, input)4 mm²
Conductor cross section solid min. (Connection data, input)0.2 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)< 1 W (400 V AC)
Conductor cross section solid max. (Connection data, output)1.5 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Standard - Electrical safety (Connection data for signaling)IEC 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Connection data for signaling)Conformance with EMC Directive 2014/30/EU
Conductor cross section flexible max. (Connection data, input)2.5 mm²
Conductor cross section flexible min. (Connection data, input)0.2 mm²
Conductor cross section flexible max. (Connection data, output)1.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Standard - Safety of transformers (Connection data for signaling)EN 61558-2-16 (air clearances and creepage distances only)
Standard – Safety extra-low voltage (Connection data for signaling)IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Limitation of mains harmonic currents (Connection data for signaling)EN 61000-3-2
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling)EN 50178/VDE 0160 (PELV)

Product Description

TRIO POWER primary switching power supply with push-in connection for rail mounting, input: three-phase, output: 24 V DC/5 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified