TRIO-DIODE/48DC/2X10/1X20 - TRIO-DIODE/48DC/2X10/1X20 2866527 PHOENIX CONTACT Redundancy module
In Stock Hot Product

TRIO-DIODE/48DC/2X10/1X20

TRIO-DIODE/48DC/2X10/1X20 2866527 PHOENIX CONTACT Redundancy module

$0.00USD
4362 in stock
Key Specifications
GTIN:4046356562973
Orderkey:2866527
Catalog page:Page 211 (C-6-2015)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356562973
Orderkey2866527
Catalog pagePage 211 (C-6-2015)
Packing unit1 pc
(Input data)10 A (Redundancy)
(Output data)
Country of originCN (China)
Custom tariff number85049091
(Ambient conditions)1x 30 A (-25°C ... 40°C)
Derating (Input data)55 °C ... 70 °C (2.5%/K)
Screw thread (General)M2,5
Efficiency (Output data)> 97 %
Net weight (Output data)0.37 kg
Stripping length (General)9 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Screw connection
Depth (Key Commercial Data)115 mm
Width (Key Commercial Data)32 mm
Height (Key Commercial Data)130 mm
Protection class (Output data)III
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
(Connection data for signaling)15 Hz ... 150 Hz, 2.3g tv= 90 min.
Degree of pollution (Dimensions)2
Connection in series (Input data)No
Degree of protection (Dimensions)IP20
Degree of protection (Output data)IP20
Assembly instructions (Output data)alignable: horizontally 0 mm, vertically 50 mm
Nominal output voltage (Input data)47.3 V DC (Input/output voltage drop of 48 V ... 0.7 V )
Weight per Piece (excluding packing)370.000 g
Screw thread (Connection data, input)M3
Shock (Connection data for signaling)15g in all directions in acc. with IEC 60068-2-27
Screw thread (Connection data, output)M2,5
Voltage (Connection data for signaling)10 V (Test Level 3)
Comments (Connection data for signaling)Criterion B
Input voltage range (Ambient conditions)30 V DC ... 56 V DC
MTBF (IEC 61709, SN 29500) (Output data)
Nominal output current (IN) (Input data)20 A (Increasing power)
Power loss nominal load max. (Input data)14 W (IOUT= 20 A)
Stripping length (Connection data, input)14 mm
Conductor cross section AWG max. (General)14
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Screw connection
Maximum input current (Ambient conditions)2x 15 A (-25°C ... 40°C)
Nominal input current (Ambient conditions)2x 10 A (-25 °C ... 55 °C)
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
UL approvals (Connection data for signaling)UL/C-UL listed UL 508
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Frequency range (Connection data for signaling)0.15 MHz ... 80 MHz
Nominal input voltage range (Ambient conditions)48 V DC
Contact discharge (Connection data for signaling)4 kV (Test Level 2)
Test field strength (Connection data for signaling)3 V/m (Test Level 2)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Low Voltage Directive (Connection data for signaling)Conformance with LV directive 2006/95/EC
Standards/regulations (Connection data for signaling)EN 61000-6-3
Vibration (operation) (Connection data for signaling)< 15 Hz, amplitude ±2.5 mm
Conductor cross section AWG max. (Connection data, input)10
Conductor cross section AWG min. (Connection data, input)20
Standard - Safe isolation (Connection data for signaling)DIN VDE 0100-410
Conductor cross section AWG max. (Connection data, output)14
Conductor cross section AWG min. (Connection data, output)24
Conductor cross section solid max. (Connection data, input)6 mm²
Conductor cross section solid min. (Connection data, input)0.5 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)7 W (IOUT= 10 A)
Conductor cross section solid max. (Connection data, output)2.5 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Standard - Electrical safety (Connection data for signaling)EN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Connection data for signaling)Conformance with EMC Directive 2014/30/EU
Conductor cross section flexible max. (Connection data, input)4 mm²
Conductor cross section flexible min. (Connection data, input)0.5 mm²
Conductor cross section flexible max. (Connection data, output)2.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Connection in acc. with standard (Connection data for signaling)CUL
Standard – Safety extra-low voltage (Connection data for signaling)IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment (Connection data for signaling)EN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling)EN 50178/VDE 0160 (PELV)

Product Description

Redundancy module with function control, 48 VDC, 2 x 10 A, 1 x 20 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty