Service time: Monday to Friday 9:00-18:00
TRIO-DIODE/12-24DC/2X10/1X20 - TRIO-DIODE/12-24DC/2X10/1X20 2866514 PHOENIX CONTACT Redundancy module
In Stock Hot Product

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 2866514 PHOENIX CONTACT Redundancy module

$0.00USD
3245 in stock
Key Specifications
:1x 20 A (-25 °C ... 55 °C)
LED:yes
Depth:115 mm
Input:2 kV (level 3 - asymmetrical: conductor to ground)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
1x 20 A (-25 °C ... 55 °C)
LEDyes
Depth115 mm
Input2 kV (level 3 - asymmetrical: conductor to ground)
Shock15g in all directions in acc. with IEC 60068-2-27
Width32 mm
Height130 mm
Output2 kV (level 3 - asymmetrical: conductor to ground)
HousingLevel 3
Voltage10 V
CommentsCriterion B
Derating55 °C ... 70 °C (2.5 %/K)
Efficiency> 97 %
Input/OutputLevel 3
Product typeRedundancy module
Screw threadM2,5
UL approvalsUL/C-UL listed UL 508
Assembly notealignable: horizontally 0 mm, vertically 50 mm
Mounting typeDIN rail mounting
Climatic class3K3 (in acc. with EN 60721)
Product familyTRIO DIODE
Status displayLED redundancy OK
Frequency range80 MHz ... 3 GHz
Type of housingSteel sheet, zinc-plated
Article revision03
Discharge in air8 kV (Air discharge)
Horizontal pitch1.8 Div.
Housing materialMetal
Protection classIII
Stripping length9 mm
Connection methodScrew connection
Contact discharge6 kV (Contact discharge)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Output descriptionContact closed when UIN1& UIN2> 8 V
Types of signalingLED
Degree of pollution2
Input voltage range10 V DC ... 30 V DC
Test field strength10 V/m
Connection in seriesno
Degree of protectionIP20
Maximum current Imax2x 15 A (-25 °C ... 40 °C)
Side element versionAluminum
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Standards/regulationsEN 61000-4-2
Tightening torque max0.5 Nm
Vibration (operation)
Input voltage range DC10 V DC ... 30 V DC
Maximum inrush current≤ 100 mA (short-circuit-proof)
Nominal output voltageUIn- 0,5 V
Note on status displayUIN1& UIN2> 8 V: LED lights up green
Tightening torque, min0.4 Nm
Maximum switching voltagemax. 60 V DC
Standard - Safe isolationDIN VDE 0100-410
MTBF (IEC 61709, SN 29500)> 10000000 h (40 °C)
Nominal input current (IN)2x 10 A (-25 °C ... 55 °C)
Transient surge protectionVaristor
Voltage drop, input/output0.5 V
Nominal input voltage range12 V DC ... 24 V DC
Nominal output current (IN)20 A (Increasing power)
Reverse polarity protection< yes60 V
Power loss nominal load max.7 W (IOUT= 10 A)
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Voltage type of supply voltageDC
Ambient temperature (operation)-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Conductor cross section AWG max.14
Conductor cross section AWG min.24
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm
Conductor cross section, rigid max.2.5 mm²
Conductor cross section, rigid min.0.2 mm²
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise immunityEN 61000-6-1
Conductor cross section flexible max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Insulation voltage input, output / housing500 V
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

Product Description

Redundancy module with functional monitoring, 12 ... 24 V DC, 2x 10 A, 1x 20 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top