| Parameter | Value |
|---|---|
| Item | Specifications |
| Weight | TH-12: 120 g approx.TH-C2P: 140 g approx. |
| Details | Sensor head + Controller |
| Product | Hot Melt Glue Detector TH |
| Material | TH-12(Sensor head): Enclosure: Polycarbonate, Indicator: Polycarbonate, Lens: SiliconeTH-C2P(Controller): Enclosure: Heat-resistant ABS, Terminal cover: Heat-resistant ABS, Front cover: Polycarbonate |
| Accessories | MS-TH-2 (Sensor head mounting bracket): 1 set, TH-B2 (Heat shield): 1 pc., OS-TH12 (Slit mask): 1 pc. |
| Part Number | TH-12CPS |
| Product name | Hot Melt Glue Detector TH (Discontinued) |
| Warm-up time | 40 sec. approx. |
| Sensing range | 10 to 300 mm 0.394 to 11.811 in(Note) Teaching is possible for this detection range. However, the detection range varies with the size of the sensing object and its temperature, ambient temperature, etc. |
| Product Number | TH-12CPS |
| Sensing object | dia.6 mm dia.0.236 in (equivalent to 3 x 10 mm 0.118 x 0.394 in) or more hot melt glue (emissivity 0.9) at +100 degrees +212 degrees Fahrenheit or more, under ambient temperature of +25 degrees +77 degrees Fahrenheit |
| Supply voltage | 12 to 24 V DC plus or minus10 % Ripple P-P 10 % or less |
| Timer function | Incorporated with approx. 40 ms fixed OFF-delay timer, switchable either effective or ineffective |
| Pollution degree | 3 (Industrial environment) |
| Ambient temperature | 0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: –10 to +60 degrees +14 to +140 degrees Fahrenheit |
| Current consumption | 100 mA or less |
| Sensitivity setting | Teaching method (Push-button operation) |
| Applicable controller | TH-C2P |
| Applicable sensor head | TH-12 |
| Level storage function | Sensitivity levels of eight channels can be stored. |
| Outputs (OUT 1, OUT 2) | PNP open-collector transistor• Maximum source current: 100 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (at 100 mA source current) |
| Response time (operation freq.) | Sensing distance 200 mm 7.874 in or less: 1 ms or less (1 to 200 Hz), Sensing distance 300 mm 11.811 in or less: 1.5 ms or less (1 to 100 Hz) |
| External channel select function | Incorporated |
| Outputs (OUT 1, OUT 2) : Output operation | OUT 1: ON when hot melt adhesive is detected (Max. 1 sec. approx.), OUT 2: OFF when the evaluated result is NG (Max. 1 sec. approx.) |
Technical specifications and performance data