| Parameter | Value |
|---|---|
| EAN | Four trillion fifty five billion six hundred twenty six million five hundred twenty one thousand one hundred ninety |
| Key order | One million twenty seven thousand seven hundred eighty one |
| (Drawings) | |
| Key selling | AAAFAB - |
| Packing unit | 50 pcs |
| Step (Drawings) | 5,08 mm |
| ETIM 5.0 (eCl@ss) | EC002638 |
| ETIM 6.0 (eCl@ss) | EC002638 |
| ETIM 7.0 (eCl@ss) | EC002638 |
| Tariff number tariff | Eighty five million three hundred sixty six thousand nine hundred ninety |
| eCl@ss 4.0 (Ratings) | Twenty seven million two hundred sixty thousand seven hundred |
| eCl@ss 4.1 (Ratings) | Twenty seven million two hundred sixty thousand seven hundred |
| eCl@ss 5.0 (Ratings) | Twenty seven million two hundred sixty thousand seven hundred |
| eCl@ss 5.1 (Ratings) | Twenty seven million two hundred sixty thousand seven hundred |
| eCl@ss 6.0 (Ratings) | Twenty seven million two hundred sixty thousand seven hundred |
| eCl@ss 7.0 (Ratings) | Twenty seven million four hundred forty thousand three hundred nine |
| eCl@ss 8.0 (Ratings) | Twenty seven million four hundred forty thousand three hundred nine |
| eCl@ss 9.0 (Ratings) | Twenty seven million four hundred forty thousand three hundred nine |
| Result (Tensile test) | Test approved |
| Minimum order quantity | 50 pcs |
| Abbreviation (Drawings) | Plug-in connector for plate circ. printed |
| Plug-in system (Drawings) | CLASSIC COMBICON |
| Number of poles (Drawings) | Five |
| Type of contact (Drawings) | Female connection |
| (Environmental conditions) | Test approved |
| Number of floors (Drawings) | One |
| Observation (Ability conex.) | According to WEEE/RoHS, without filaments according to IEC 60068-2-82/JEDEC JESD 201 |
| Family of articles (Drawings) | TFKC 2,5/..-STF |
| Type of connection (Drawings) | Connection by spring loaded push-in |
| Visual Control (Tensile test) | Test passed DIN en 60512-1-1:2003-01 |
| Number of potential (Drawings) | Five |
| Check dimensions (Tensile test) | Test passed DIN en 60512-1-2:2003-01 |
| Number of cycles (Tensile test) | Twenty five |
| Number of connections (Drawings) | Ten |
| Material contact (Ability conex.) | Cu alloy |
| Unit weight (excluding packaging) | 12,340 g |
| Effort cold (Checks resistance (B)) | -40 °C/2 h |
| Isolation (Material data - contact) | PA |
| Isolation (Material data - housing) | PBT |
| Resistance of prints (Tensile test) | Test passed DIN en 60068-2-70:1996-07 |
| Step (Material data: drive element) | 5,08 mm |
| Strength trial-by-polo (Tensile test) | 40 N |
| (Connection and method of connection) | 2.5 mm2 / flexible / > 50 N |
| Average (Material data: drive element) | 20,32 mm |
| Polarization and coding (Tensile test) | Test passed DIN en 60512-13-5:2006-11 |
| Thermal stress (Checks resistance (B)) | 100 °C/168 h |
| Type of packaging (Product dimensions) | packaged in box |
| Color housing (Material data - contact) | black (9005) |
| Cycles of plug (Mechanical testing (A)) | Twenty five |
| Specification of the test (Tensile test) | DIN EN 60512-15-1:2009-03 |
| plug-in (Characteristic data electrical) | yes |
| Fatigue corrosion (Checks resistance (B)) | 0,2 dmThreeSOTwoin 300 dmThree/40 °C/1 cycle |
| Rated current (Properties of the article) | 12 To |
| Rated voltage (Properties of the article) | 320 V |
| (Checks and environmental resistance (E)) | No dangerous substances above the thresholds |
| Tension sizing (Properties of the article) | 320 V |
| Width [ w ] (Material data: drive element) | 35,2 mm |
| Ac voltage bearable (Checks resistance (B)) | 2,21 kV |
| Height [ h ] (Material data: drive element) | 22,1 mm |
| Length [ l ] (Material data: drive element) | 25,7 mm |
| Ac voltage bearable (Mechanical testing (A)) | 2,21 kV |
| Designation packing Units (Product dimensions) | Units |
| Specification of the test (Temperature cycles) | DIN EN 61984 (VDE 0627) |
| Characteristics of the surface (Ability conex.) | tinning of malleable cast iron |
| Contact resistance ROne (Mechanical testing (A)) | 2 mΩ |
| Contact resistance RTwo (Mechanical testing (A)) | 2,2 mΩ |
| Force to the plug by polo approx. (Tensile test) | 10 N |
| Outline dimensions (Material data: drive element) | |
| Specification of the test (Checks resistance (B)) | DIN EN ISO 6988:1997-03 |
| Specification of the test (Essays on climate (D)) | DIN EN 61984 (VDE 0627):2009-11 |
| Temperature cycles (Electrical testing: function) | One hundred ninety two |
| The result of the test (Environmental conditions) | Test approved |
| Length of peeling (Characteristic data electrical) | 10 mm |
| Specification of the test (Mechanical testing (A)) | DIN EN 60512-9-1 (VDE 0687-512-9-1):2010-12 |
| Tensile test (Connection and method of connection) | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Group insulating material (Material data - contact) | I |
| Room temperature (service) (Indications of packing) | -40 °C ... 100 °C (in function of the curve derating) |
| Type of connection (Characteristic data electrical) | Connection by spring loaded push-in |
| CTI according to IEC 60112 (Material data - contact) | Six hundred |
| CTI according to IEC 60112 (Material data - housing) | Six hundred |
| China RoHS (Checks and environmental resistance (E)) | Space of time for the intended use: unlimited = FEUP-e |
| Force when unplugging per pole approx. (Tensile test) | 9.5 N |
| Tension and sizing (II/2) (Properties of the article) | 630 V |
| Tension and sizing (III/2) (Properties of the article) | 320 V |
| Ambient temperature (assembly) (Indications of packing) | -5 °C ... 100 °C |
| Specification of the test (Electrical testing: function) | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Voltage shock endurable level sea (Checks resistance (B)) | To 4.8 kV |
| Metal surface area of contact (top layer) (Ability conex.) | Tin (4 - 8 ám Sn) |
| Specification of the test (Lines of flight and air spaces) | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Voltage shock endurable level sea (Mechanical testing (A)) | To 4.8 kV |
| Result-Degree of protection IP Code (Essays on climate (D)) | Protection against contact of fingers with finger proof IP20 |
| Section of conductor rigid (Characteristic data electrical) | 0,2 mm2 ... 2.5 mm2 |
| Transient voltage design (II/2) (Properties of the article) | 4 kV |
| Gauge male a x b / Diameter (Characteristic data electrical) | 2.8 mm x 2.0 mm/2.0 mm |
| Transient voltage design (III/2) (Properties of the article) | 4 kV |
| Transient voltage design (III/3) (Properties of the article) | 4 kV |
| Check the connection of conductors (Environmental conditions) | The stripped end of the conductor is the largest you can insert completely and without excessive force, into the opening of the point of embornaje. |
| Test current (maximum section) (Electrical testing: function) | 12 TO DC |
| Insulation resistance Pole-contiguous (Mechanical testing (A)) | 1 TΩ |
| Section of flexible conductor (Characteristic data electrical) | 0,2 mm2 ... 2.5 mm2 |
| Check: connect and drop multiple times (Environmental conditions) | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Section of conductor AWG / kcmil (Characteristic data electrical) | 24 ... 12 |
| Ambient temperature (storage / transport) (Indications of packing) | -40 °C ... 70 °C |
| Class of flammability according to UL 94 (Material data - contact) | V0 |
| Class of flammability according to UL 94 (Material data - housing) | V0 |
| Test current (minimum cross-section) (Electrical testing: function) | 4 TO DC |
| Metal surface of the point of embornaje (top layer) (Ability conex.) | Tin (4 - 8 ám Sn) |
| DiagramType: TFKC 2,5/...-STF-5,08 with MSTBV 2,5/...-GF-5,08 (Drawings) | |
| Specification of the test (Curves of current capacity / curves derating) | DIN EN 61984 (VDE 0627) |
| Specification of the test (Mechanical testing according to the standards) | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Checking of damage in the conductors and loosening (Environmental conditions) | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Air spaces and lines of flight (Mechanical testing according to the standards) | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Force to the plug by polo approx. (Curves of current capacity / curves derating) | 10 N |
| Portacontactos used requirement >20 N (Curves of current capacity / curves derating) | Test approved |
| Force when unplugging per pole approx. (Curves of current capacity / curves derating) | 9.5 N |
| Height of building (height without the shank of soldering) (Material data: drive element) | 23 mm |
| Minimum value of the line of flight (II/2) (Mechanical testing according to the standards) | 3.2 mm |
| Ignition temperature of filaments GWIT according to en 60695-2-13 (Material data - contact) | Seven hundred seventy five |
| Minimum value of the line of flight (III/2) (Mechanical testing according to the standards) | 3 mm |
| Minimum value of the line of flight (III/3) (Mechanical testing according to the standards) | 4 mm |
| Section of flexible conductor with toe, with plastic sleeve (Characteristic data electrical) | 0.25 mm2 ... 2.5 mm2 |
| Number of flammability of filaments GWFI according to en 60695-2-12 (Material data - contact) | Eight hundred fifty |
| Section of the driver / type of driver / traction force (Connection and method of connection) | 0,2 mm2 / stiff / > 10 N |
| Section of flexible conductor with toe cap, without plastic sleeve (Characteristic data electrical) | 0.25 mm2 ... 2.5 mm2 |
| Temperature test of the hardness for the balls according to en 60695-10-2 (Material data - contact) | 125 °C |
| Minimum value of air gap - field inhomogéneo (II/2) (Mechanical testing according to the standards) | 3 mm |
| Minimum value of air gap - field inhomogéneo (III/2) (Mechanical testing according to the standards) | 3 mm |
| Minimum value of air gap - field inhomogéneo (III/3) (Mechanical testing according to the standards) | 3 mm |
| Requirement of impossibility of confusion when connecting >20 N (Curves of current capacity / curves derating) | Test approved |
| 2 conductors with same cross section, flexible with toe cap TWIN with plastic sleeve (Characteristic data electrical) | 0.5 mm2 ... 1.5 mm2 |
Technical specifications and performance data