| Parameter | Value |
|---|---|
| GTIN | 4046356768832 |
| Orderkey | 2903805 |
| (Function) | 10000 cycles (5 A / 250 V AC) |
| Catalog page | Page 348 (C-6-2017) |
| Depth (Note) | 62 mm |
| Packing unit | 1 pc |
| Width (Note) | 72 mm |
| Height (Note) | 90 mm |
| (Analog inputs) | EN 50121-4 |
| (Digital inputs) | 50 Ω (Current inputs) |
| Country of origin | DE (Germany) |
| (Serial interface) | 1900 MHz (1 W (EGSM)) |
| FCC (Analog inputs) | Part 15.107(a), 15.109(a) |
| ATEX (Analog inputs) | II 3 G Ex nA nC IIC T4 Gc X |
| Custom tariff number | 85176200 |
| (Ambient conditions) | 134 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) |
| Altitude (Dimensions) | 2000 m |
| Output name (Function) | Relay output |
| Signal (Analog inputs) | ± 1 kV (Data line, asymmetrical) |
| Contact type (Function) | N/O contact |
| GPRS (Serial interface) | Multislot Class 10 |
| Comments (Analog inputs) | Criterion B |
| FCC (Ambient conditions) | Part 15.107(a), 15.109(a) |
| ATEX (Ambient conditions) | II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
| MTTF (Ambient conditions) | 692 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| Interface 1 (Power supply) | USB 2.0 |
| Precision (Digital inputs) | ± 0.1 % |
| Conformance (Analog inputs) | CE-compliant |
| Resolution (Digital inputs) | 15 bit |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Frequency (Serial interface) | 850 MHz (2 W (EGSM)) |
| Number of outputs (Function) | 4 |
| Input signal (Digital inputs) | Current or voltage |
| Switching capacity (Function) | 1500 VA |
| Supply voltage range (General) | 10 V DC ... 60 V DC |
| Frequency range (Analog inputs) | 0.15 MHz ... 80 MHz |
| Net weight (Ambient conditions) | 253 g |
| Conformance (Ambient conditions) | CE-compliant |
| Connection method (Power supply) | Mini-USB type B, 5-pos. |
| Input impedance (Digital inputs) | 600 kΩ (Voltage inputs) |
| Noxious gas test (Analog inputs) | ISA-S71.04-1985 G3 Harsh Group A |
| Contact discharge (Analog inputs) | ± 6 kV |
| Degree of protection (Dimensions) | IP20 |
| Number of inputs (Digital inputs) | 2 |
| Electrical service life (Function) | 5000 cycles (6 A / 250 V AC) |
| Indirect discharge (Analog inputs) | ± 6 kV |
| Max. current consumption (General) | 80 mA |
| Number of inputs (Digital outputs) | 4 |
| Transmission length (Power supply) | ≤ 3 m (only for configuration and diagnostics) |
| Maximum switching voltage (Function) | 250 V AC |
| Minimum switching voltage (Function) | 5 V AC |
| Weight per Piece (excluding packing) | 253.000 g |
| Current input signal (Digital inputs) | 0 mA ... 20 mA |
| Housing material (Ambient conditions) | Polycarbonate |
| Standards/regulations (Analog inputs) | EN 50360 |
| Typical current consumption (General) | 50 mA (24 V DC) |
| Voltage input signal (Digital inputs) | 0 V DC ... 60 V DC |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Limiting continuous current (Function) | 6 A AC |
| Conducted noise emission (Analog inputs) | Class B, area of application: Industry and residential |
| Interface description (Serial interface) | GSM / GPRS |
| Description of the input (Digital inputs) | Analog input |
| Web-based management (Wireless interface) | yes |
| Conductor cross section AWG max. (General) | 14 |
| Conductor cross section AWG min. (General) | 24 |
| Description of the input (Digital outputs) | Digital input |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C (for derating, see technical documentation) |
| Conductor cross section solid max. (General) | 2.50 mm² |
| Conductor cross section solid min. (General) | 0.20 mm² |
| Electromagnetic compatibility (Analog inputs) | Conformance with EMC Directive 2014/30/EU |
| Permissible humidity (operation) (Dimensions) | 0 % ... 95 % |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Conductor cross section flexible max. (General) | 2.50 mm² |
| Conductor cross section flexible min. (General) | 0.20 mm² |
| Electromagnetic compatibility (Ambient conditions) | Conformance with EMC Directive 2014/30/EU |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Max. AWG conductor cross section, flexible (General) | 14 |
| Min. AWG conductor cross section, flexible (General) | 24 |
| Switching threshold "0" signal in reference to UN (Digital outputs) | ≤ 0.3 |
| Switching threshold "1" signal in reference to UN (Digital outputs) | ≥ 0.7 |
Technical specifications and performance data