| Parameter | Value |
|---|---|
| Pitch | 2.54 mm |
| Result | Test passed |
| Amplitude | 0.15 mm (10 Hz ... 58.1 Hz) |
| Frequency | 10 - 150 - 10 Hz |
| Width [w] | 29.3 mm |
| Height [h] | 37.15 mm |
| Length [l] | 16.3 mm |
| Pulse shape | Semi-sinusoidal |
| Sweep speed | 1 octave/min |
| Temperature | 850 °C |
| Acceleration | 15g |
| Product type | DIN rail connector |
| Mounting type | DIN rail mounting |
| No. of cycles | 25 |
| Specification | IEC 60512-5-1:2002-02 |
| Product family | TBUS-8-2..-PS |
| Recommendation | Material of contact pads for bus connector, galvanic gold (hard gold) |
| Shock duration | 11 ms |
| Thermal stress | 100 °C/168 h |
| Color (Housing) | light grey (7035) |
| Test directions | X-, Y- and Z-axis (pos. and neg.) |
| Contact material | Cu alloy |
| Corrosive stress | 0.2 dm3SO2on 300 dm3/40 °C/1 cycle |
| Time of exposure | 30 s |
| Cross section AWG | (converted acc. to IEC) |
| Type of packaging | packed in cardboard |
| Contact resistance | 3.7 mΩ |
| Nominal current IN | 6 A (parallel contacts) |
| Nominal voltage UN | 32 V |
| Degree of pollution | 3 |
| Insulating material | PA |
| Number of positions | 8 |
| Outer packaging type | Carton |
| Rated voltage (II/2) | 32 V |
| Contact resistance R1 | 3.7 mΩ |
| Contact resistance R2 | 3.85 mΩ |
| Rated voltage (III/2) | 32 V |
| Test duration per axis | 2.5 h |
| Surface characteristics | gold-plated |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Rated surge voltage (II/2) | 1.5 kV |
| Tested number of positions | 8 |
| Insertion/withdrawal cycles | 25 |
| Rated surge voltage (III/2) | 1.5 kV |
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C ... 105 °C (dependent on the derating curve) |
| Rated insulation voltage (II/2) | 32 V |
| Rated insulation voltage (III/2) | 32 V |
| minimum creepage distance (II/2) | 0.53 mm |
| Power-frequency withstand voltage | 0.84 kV |
| minimum creepage distance (III/2) | 0.53 mm |
| Withdraw strength per pos. approx. | 2.5 N |
| Insertion strength per pos. approx. | 2.8 N |
| Relative humidity (storage/transport) | 30 % ... 70 % |
| Flammability rating according to UL 94 | V0 |
| Impulse withstand voltage at sea level | 1.75 kV |
| Ambient temperature (storage/transport) | -40 °C ... 55 °C |
| Contact holder in insertRequirements >20 N | Test passed |
| minimum clearance value - non-homogenous field (II/2) | 0.5 mm |
| minimum clearance value - non-homogenous field (III/2) | 0.5 mm |
Technical specifications and performance data
Installation and operation guide