Service time: Monday to Friday 9:00-18:00
STTBS 2,5-PE - STTBS 2,5-PE 3038480 PHOENIX CONTACT Protective conductor double-level terminal block
In Stock Hot Product

STTBS 2,5-PE

STTBS 2,5-PE 3038480 PHOENIX CONTACT Protective conductor double-level terminal block

$6.31USD
1631 in stock
Key Specifications
:1204517 SZF 1-0,6X3,5
Note:Please observe the current carrying capacity of the DIN rails.
Color:green-yellow
Width:5.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
1204517 SZF 1-0,6X3,5
NotePlease observe the current carrying capacity of the DIN rails.
Colorgreen-yellow
Width5.2 mm
Height78 mm
ResultTest passed
output(Permanent)
SpectrumService life test category 2, bogie-mounted
ASD level6.12 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 250 Hz
Pulse shapeHalf-sine
Acceleration3.12g
Product typeGround terminal block
Mounting typeNS 35/7,5
SpecificationDIN EN 50155 (VDE 0115-200):2008-03
Grounding footYes
Identification II 2 G Ex eb IIC Gb
Number of rows2
Shock duration18 ms
End cover width2.2 mm
Open side panelYes
Test directionsX-, Y- and Z-axis
Article revision09
Stripping length8 mm ... 10 mm
Cross section AWG28 ... 12 (converted acc. to IEC)
Depth on NS 35/1562.5 mm
Degree of pollution3
Depth on NS 35/7,555 mm
Insulating materialPA
Rated surge voltage6 kV
Overvoltage categoryIII
Nominal cross section2.5 mm²
Number of connections4
Test duration per axis5 h
Connection capacity AWG28 ... 12
Rated cross section AWG14
Ex-certified accessories3038503 D-STTBS 2,5
Connection capacity rigid0.08 mm² ... 4 mm²
Insulating material groupI
Internal cylindrical gageA3
Operating temperature range-60 °C ... 110 °C
Connection capacity flexible0.08 mm² ... 2.5 mm²
Conductor cross section rigid0.08 mm² ... 4 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level2
Conductor cross section flexible0.08 mm² ... 2.5 mm²
Connection in acc. with standardIEC 60947-7-2
Permissible humidity (operation)20 % ... 90 %
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG]28 ... 14 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition0.77 W
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C

Product Description

Double-deck terminal block conductor protection, number of connections: 4, connection type: Spring connection, 1st and 2nd floor, cross-section: 0.08 mm² - 4 mm², mounting class: NS 35/7.5, NS 35/15,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top