| Parameter | Value |
|---|---|
| 1204517 SZF 1-0,6X3,5 | |
| Note | Please observe the current carrying capacity of the DIN rails. |
| Color | green-yellow |
| Width | 5.2 mm |
| Height | 78 mm |
| Result | Test passed |
| output | (Permanent) |
| Spectrum | Service life test category 2, bogie-mounted |
| ASD level | 6.12 (m/s²)²/Hz |
| Frequency | f1= 5 Hz to f2= 250 Hz |
| Pulse shape | Half-sine |
| Acceleration | 3.12g |
| Product type | Ground terminal block |
| Mounting type | NS 35/7,5 |
| Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
| Grounding foot | Yes |
| Identification | II 2 G Ex eb IIC Gb |
| Number of rows | 2 |
| Shock duration | 18 ms |
| End cover width | 2.2 mm |
| Open side panel | Yes |
| Test directions | X-, Y- and Z-axis |
| Article revision | 09 |
| Stripping length | 8 mm ... 10 mm |
| Cross section AWG | 28 ... 12 (converted acc. to IEC) |
| Depth on NS 35/15 | 62.5 mm |
| Degree of pollution | 3 |
| Depth on NS 35/7,5 | 55 mm |
| Insulating material | PA |
| Rated surge voltage | 6 kV |
| Overvoltage category | III |
| Nominal cross section | 2.5 mm² |
| Number of connections | 4 |
| Test duration per axis | 5 h |
| Connection capacity AWG | 28 ... 12 |
| Rated cross section AWG | 14 |
| Ex-certified accessories | 3038503 D-STTBS 2,5 |
| Connection capacity rigid | 0.08 mm² ... 4 mm² |
| Insulating material group | I |
| Internal cylindrical gage | A3 |
| Operating temperature range | -60 °C ... 110 °C |
| Connection capacity flexible | 0.08 mm² ... 2.5 mm² |
| Conductor cross section rigid | 0.08 mm² ... 4 mm² |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Number of shocks per direction | 3 |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Number of connections per level | 2 |
| Conductor cross section flexible | 0.08 mm² ... 2.5 mm² |
| Connection in acc. with standard | IEC 60947-7-2 |
| Permissible humidity (operation) | 20 % ... 90 % |
| Flammability rating according to UL 94 | V0 |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Conductor cross section, flexible [AWG] | 28 ... 14 (converted acc. to IEC) |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Static insulating material application in cold | -60 °C |
| Maximum power dissipation for nominal condition | 0.77 W |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
Technical specifications and performance data