| Parameter | Value |
|---|---|
| GTIN | 4017918899752 |
| Orderkey | 3038257 |
| Catalog page | Page 205 (C-3-2015) |
| Packing unit | 25 pc |
| Width (General) | 12 mm |
| Length (General) | 95 mm |
| Country of origin | RO (Romania) |
| Custom tariff number | 85369010 |
| Minimum order quantity | 25 pc |
| Height NS 35/15 (General) | 56.5 mm |
| Height NS 35/7,5 (General) | 49 mm |
| Note (Key Commercial Data) | Assembly instruction:In order to securely fix the neutral busbar in place, support brackets must be placed at the beginning and end of each terminal strip as well as every 20 cm on longer terminal strips.The corresponding support brackets can be found at phoenixcontact.net/products |
| Color (Key Commercial Data) | gray |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Stripping length (Dimensions) | 18 mm |
| Connection method (Dimensions) | Spring-cage connection |
| Weight per Piece (excluding packing) | 34.080 g |
| Open side panel (Key Commercial Data) | Yes |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Internal cylindrical gage (Dimensions) | A7 |
| Number of levels (Key Commercial Data) | 1 |
| Nominal current IN (Key Commercial Data) | 76 A |
| Nominal voltage UN (Key Commercial Data) | 400 V |
| Degree of pollution (Key Commercial Data) | 3 |
| Insulating material (Key Commercial Data) | PA |
| Rated surge voltage (Key Commercial Data) | 6 kV |
| Maximum load current (Key Commercial Data) | 76 A (with 25 mm² conductor cross section) |
| Overvoltage category (Key Commercial Data) | III |
| Nominal cross section (Key Commercial Data) | 16 mm² |
| Number of connections (Key Commercial Data) | 2 |
| Conductor cross section AWG max. (Dimensions) | 4 |
| Conductor cross section AWG min. (Dimensions) | 24 |
| Conductor cross section solid max. (Dimensions) | 25 mm² |
| Conductor cross section solid min. (Dimensions) | 0.2 mm² |
| Insulating material group (Key Commercial Data) | I |
| Conductor cross section flexible max. (Dimensions) | 16 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.2 mm² |
| Connection in acc. with standard (Connection data) | IEC 60947-7-1 |
| Connection in acc. with standard (Key Commercial Data) | IEC 60947-7-1 |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Maximum power dissipation for nominal condition (Key Commercial Data) | 2.43 W |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 16 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 16 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 0.25 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) | 4 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions) | 1.5 mm² |