Service time: Monday to Friday 9:00-18:00
STEP3-PS/1AC/48DC/2.5/PT - STEP3-PS/1AC/48DC/2.5/PT 1285035 PHOENIX CONTACT Primary Switching Power Supplies, STEPPOWER, Push-in Connec..
In Stock Hot Product

STEP3-PS/1AC/48DC/2.5/PT

STEP3-PS/1AC/48DC/2.5/PT 1285035 PHOENIX CONTACT Primary Switching Power Supplies, STEPPOWER, Push-in Connec..

$121.64USD
129 in stock
Key Specifications
:95 V AC ... 120 V AC  10 % (96 W)
Color:green
Depth:61 mm
Input:asymmetrical 4 kV (Test Level 4)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
95 V AC ... 120 V AC  10 % (96 W)
Colorgreen
Depth61 mm
Inputasymmetrical 4 kV (Test Level 4)
Width72 mm
rigid0.2 mm² ... 2.5 mm²
Height90 mm
Outputasymmetrical 2 kV (Test Level 3)
LED offSupply voltage input AC not present (Off)
Voltage10 V (Test Level 3)
CommentsCriterion A
Derating> 50 °C ... 70 °C (2 % / K)
FunctionVisual operating state display
Position1.x
flexible0.2 mm² ... 2.5 mm²
Frequency50 Hz
Rise timetyp. 100 ms (UOut= 10 % ... 90 %)
EN 61010-1II (≤ 5000 m)
EN 62477-1III (≤ 2000 m)
Efficiency> 94 % (120 V AC)
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Voltage dip70 %
rigid (AWG)24 ... 14 (Cu)
Crest factortyp. 1,64 (120 V AC)
Product typePower supply
Mounting typeDIN rail or direct mounting
No-load proofyes
IdentificationUL/C-UL Listed UL 61010-1
Inrush currenttyp. 35 A
Noise emissionEN 55016
Noise immunityEN 61000-6-2:2005
Product familySTEP POWER
Switch-on timetyp. 2 s
Additional textClass 3
Frequency range0 kHz ... 2 kHz
Residual rippletyp. 100 mVPP
Discharge in air8 kV (Test Level 3)
Horizontal pitch4 Div. (DIN 43880)
Housing materialPlastic
Maximum altitude≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
Number of phases1.00
Position marking1.1, 1.2 (L), 1.3, 1.4 (N)
Protection classII (in closed control cabinet)
Stripping length10 mm (rigid/flexible/ferrule without plastic sleeve)
Connection methodPush-in connection
Contact discharge6 kV (Test Level 3)
Control deviation< 0.5 % (Static load change 10 % ... 90 %)
Device mains fuse4 A internal (device protection), slow-blow
Mounting positionhorizontal DIN rail NS 35, EN 60715
Number of periods25 periods
Output power (PN)120 W
Shock (operation)18 ms, 30g, per spatial direction (IEC 60068-2-27)
Protective circuitTransient surge protection; Varistor
Types of signalingLED DC OK – signal state operation (UN= 24 V DC, IOut= IN)
Current consumption1.11 A (120 V AC)
Degree of pollution2
Dimensional drawing
Foot latch materialPolyamid
Input voltage range120 V AC ... 240 V AC  10 % (120 W)
Short-circuit-proofyes
Test field strength10 V/m (Test Level 3)
Connection in seriesyes, for increased output voltage
Degree of protectionIP20
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 19 ms (120 V AC)
Standard designationElectrical safety
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically
Interference emissionInterference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial)
LED on (green), DC OKUOut>44 V DC (on)
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Standards/regulationsEN 61000-3-2
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6)
Connection in parallelyes, for increasing power and redundancy with diode
Nominal output voltage48 V DC
Discharge current to PE< 0.25 mA
With protective coatingNo
Conducted noise emissionEN 55016
Standards/specificationsIEC 61010-1 (SELV)
MTBF (IEC 61709, SN 29500)> 1372000 h (25 °C)
Feedback voltage resistance≤ 60 V DC
Nominal output current (IN)2.5 A (120 W)
Supply system configurationStar network (TN, TT, IT (PE))
Power loss nominal load max.< 5.7 W (230 V AC)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Inrush current integral (I2t)typ. 0.03 A2s
Typical national grid voltage120 V AC
Voltage type of supply voltageAC
Ambient temperature (operation)-10 °C ... 70 °C (Derating: > 50 °C; 2 %/K)
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom30 mm / 30 mm
Maximum no-load power dissipation< 0.21 W (230 V AC)
Minimum no-load power dissipation< 0.21 W (120 V AC)
Environmental protection directiveRoHS Directive 2011/65/EU
Minimum nominal load power dissipation< 7.7 W (120 V AC)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)
flexible with ferrule with plastic sleeve0.2 mm² ... 1 mm²
Ambient temperature (start-up type tested)-25 °C
Setting range of the output voltage (USet)48 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
flexible with ferrule without plastic sleeve0.5 mm² ... 1.5 mm²
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Protection against overvoltage at the output (OVP)< 60 V DC

Product Description

Primary-switched power supply unit, STEP POWER, Push-in connection, DIN rail or direct mounting, input: 1-phase, output: 48 V DC / 2.5 A, adjustable from 48 V DC ... 56 V DC, PoE application up to 120
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top