| Parameter | Value |
|---|---|
| GTIN | 4046356519922 |
| Orderkey | 2868693 |
| Catalog page | Page 298 (C-4-2017) |
| Packing unit | 1 pc |
| Country of origin | PL (Poland) |
| (Charging process) | 15 Hz ... 150 Hz, 2.3g, 90 min. |
| Custom tariff number | 85371091 |
| Screw thread (General) | M3 |
| Shock (Charging process) | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Stripping length (General) | 6.5 mm |
| Voltage (Charging process) | 10 V (Test Level 3) |
| Climatic class (Dimensions) | 3K3 (in acc. with EN 60721) |
| Comments (Charging process) | Criterion B |
| Connection method (General) | Screw connection |
| Depth (Key Commercial Data) | 61 mm |
| Width (Key Commercial Data) | 108 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 90 mm |
| UL approvals (Charging process) | UL Listed UL 508 |
| Degree of pollution (Dimensions) | 2 |
| Net weight (General output data) | 0.46 kg |
| Degree of protection (Dimensions) | IP20 |
| Noise immunity (Charging process) | EN 61000-6-2 |
| Frequency range (Charging process) | 0.15 MHz ... 80 MHz |
| Input voltage (Ambient conditions) | 12 V DC |
| IQ technology (General output data) | no |
| Memory medium (General output data) | Lithium polymer |
| Nominal output voltage (Input data) | 12 V DC |
| Contact discharge (Charging process) | 4 kV (Test Level 2) |
| Weight per Piece (excluding packing) | 595.400 g |
| Screw thread (Connection data, input) | M3 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 25; |
| Protection class (General output data) | III |
| Screw thread (Connection data, output) | M3 |
| Test field strength (Charging process) | 3 V/m (Test Level 2) |
| Mounting position (General output data) | horizontal DIN rail NS 35, EN 60715 |
| Input voltage range (Ambient conditions) | 10 V DC ... 16.5 V DC |
| Nominal output current (IN) (Input data) | 4 A (0 °C ... 40 °C) |
| Standards/regulations (Charging process) | EN 61000-6-3 |
| Vibration (operation) (Charging process) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| Stripping length (Connection data, input) | 6.5 mm |
| Conductor cross section AWG max. (General) | 12 |
| Conductor cross section AWG min. (General) | 24 |
| Connection method (Connection data, input) | Screw connection |
| Nominal input voltage (Ambient conditions) | 12 V DC |
| Stripping length (Connection data, output) | 6.5 mm |
| Assembly instructions (General output data) | alignable: horizontally 0 mm, vertically 50 mm |
| Input fuse, integrated (Ambient conditions) | 7 A (slow-blow, internal) |
| Ambient temperature (operation) (Dimensions) | 0 °C ... 40 °C |
| Conductor cross section solid max. (General) | 2.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Fixed connect threshold (Ambient conditions) | < 10 V |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Current consumption (idle) (Ambient conditions) | < 30 mA |
| Standard - Electrical safety (Charging process) | EN 60950-1/VDE 0805 (SELV) |
| Variable connect threshold (Ambient conditions) | 1 V / 1 s |
| Electromagnetic compatibility (Charging process) | Conformance with EMC Directive 2014/30/EU |
| MTBF (IEC 61709, SN 29500) (General output data) | > 1997000 h (40 °C) |
| Current consumption (maximum) (Ambient conditions) | 6 A |
| Connection in acc. with standard (Charging process) | CUL |
| Ambient temperature (storage/transport) (Dimensions) | -20 °C ... 45 °C |
| Efficiency (Output data (12 V DC battery operation)) | > 97.4 % (Mains operation, with charged energy storage) |
| Quality check of battery (Connection data for signaling) | Yes, every time it is charged and cyclically once a month |
| Conductor cross section AWG max. (Connection data, input) | 12 |
| Conductor cross section AWG min. (Connection data, input) | 24 |
| Deep discharge protection (Connection data for signaling) | < 15 V DC |
| Conductor cross section AWG max. (Connection data, output) | 12 |
| Conductor cross section AWG min. (Connection data, output) | 24 |
| Conductor cross section solid max. (Connection data, input) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, input) | 0.2 mm² |
| Current consumption (charging process) (Ambient conditions) | < 0.8 A (Charging (ICharge = max, IOut = 0)) |
| Max. permissible relative humidity (operation) (Dimensions) | ≤ 95 % (at 25 °C, non-condensing) |
| Conductor cross section solid max. (Connection data, output) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, output) | 0.2 mm² |
| Conductor cross section flexible max. (Connection data, input) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, input) | 0.2 mm² |
| Nominal output voltage (Output data (12 V DC mains operation)) | 12 V DC |
| Conductor cross section flexible max. (Connection data, output) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, output) | 0.2 mm² |
| Nominal output current (IN) (Output data (12 V DC mains operation)) | 4 A (0 °C ... 40 °C) |
| Output voltage range (depends on the input voltage) (Output data (12 V DC mains operation)) | 10 V DC ... 15 V DC (UOut= UIn (t-1)) |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Charging process) | EN 50178/VDE 0160 (PELV) |
Technical specifications and performance data
Installation and operation guide