Service time: Monday to Friday 9:00-18:00
STEP-PS/48AC/24DC/0.5 - STEP-PS/48AC/24DC/0.5 2868716 PHOENIX CONTACT Power supply unit
In Stock Hot Product

STEP-PS/48AC/24DC/0.5

STEP-PS/48AC/24DC/0.5 2868716 PHOENIX CONTACT Power supply unit

$0.00USD
3529 in stock
Key Specifications
:60 V DC ... 80 V DC
Depth:61 mm
Input:2 kV (Test Level 3 - asymmetrical)
Shock:18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
60 V DC ... 80 V DC
Depth61 mm
Input2 kV (Test Level 3 - asymmetrical)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Width18 mm
Height90 mm
Output2 kV (Test Level 3 - asymmetrical)
Voltage10 V
CommentsCriterion A
Derating55 °C ... 70 °C (2.5 %/K)
Efficiency> 81 % (for 48 V AC and nominal values)
Input fuse1.25 A (slow-blow, internal)
Input/OutputTest Level 3
Output power12 W
Product typePower supply
Screw threadM3
UL approvalsUL/C-UL listed UL 508
Assembly notealignable: 0 mm horizontally, 30 mm vertically
Mounting typeDIN rail mounting
Climatic class3K3 (in acc. with EN 60721)
Inrush current< 10 A (typical)
Product familySTEP POWER
Status display"DC OK" LED green
Frequency range80 MHz ... 3 GHz
Residual ripple< 30 mVPP(20 MHz)
Article revision03
Discharge in air8 kV (Test Level 3)
Horizontal pitch1 Div.
Housing materialPlastic
Number of phases1.00
Protection classII (in closed control cabinet)
Stripping length6.5 mm
Connection methodScrew connection
Contact discharge6 kV (Test Level 3)
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Rail applicationsEN 50121-4
AC frequency range45 Hz ... 65 Hz
Frequency range DC0 Hz
Types of signalingLED
Current consumption0.5 A (43 V AC)
Degree of pollution2
Foot latch materialPOM (Polyoxymethylene)
Input voltage range43 V AC ... 52 V AC
Output current Imax1 A
Test field strength10 V/m (Test Level 3)
Connection in seriesyes
Degree of protectionIP20
Mains buffering timetyp. 15 ms (48 V AC)
Overvoltage categoryIII
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Output characteristicU/I
Standards/regulationsEN 61000-4-2
Tightening torque max0.6 Nm
Typical response time< 0.5 s
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Connection in parallelyes, for redundancy and increased capacity
Input voltage range AC43 V AC ... 52 V AC
Input voltage range DC60 V DC ... 80 V DC
Nominal output voltage24 V DC
Note on status displayUOUT> 21.5 V: LED lights up
Power factor (cos phi)0.7
Tightening torque, min0.5 Nm
With protective coatingno
Nominal power consumption21 VA
Operating voltage displayGreen LED
Standard - Safe isolationDIN VDE 0100-410
MTBF (IEC 61709, SN 29500)> 1860000 h (40 °C)
Feedback voltage resistance≤ 35 V DC
Nominal input voltage range48 V AC
Nominal output current (IN)0.5 A (-25 °C ... 55 °C)
Power loss nominal load max.< 3.4 W
Standard - Electrical safetyIEC 62368-1 (SELV)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Inrush current integral (I2t)< 0.1 A2s
Voltage type of supply voltageAC/DC
Ambient temperature (operation)-25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
Insulation voltage input/output4 kV AC (type test)
Conductor cross section AWG max.12
Conductor cross section AWG min.24
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom30 mm / 30 mm
SIL in accordance with IEC 615080
Maximum no-load power dissipation< 0.3 W
Standard - Safety of transformersEN 61558-2-16
Conductor cross section, rigid max.2.5 mm²
Conductor cross section, rigid min.0.2 mm²
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise immunityEN 61000-6-1
Peak switching voltages nominal load< 20 mVPP(20 MHz)
Conductor cross section flexible max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60204-1 (PELV)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Protection against overvoltage at the output (OVP)< 35 V DC
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

Product Description

STEP POWER primary switching power supply for rail mounting, input: single-phase, output: 24 V DC/0.5 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top