Key Specifications
:95 V DC ... 250 V DC
CSA:CSA-C22.2 No. 107.1-01
Input:2 kV (Test Level 3 - asymmetrical)
Shock:18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
95 V DC ... 250 V DC
CSACSA-C22.2 No. 107.1-01
Input2 kV (Test Level 3 - asymmetrical)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Width90 mm
Height90 mm
Output2 kV (Test Level 3 - asymmetrical)
Voltage10 V (Test Level 3)
CommentsCriterion B
Derating55 °C ... 70 °C (2.5 %/K)
Rise time< 0.5 s (UOUT(10 % ... 90 %))
Temp codeT4A (60 °C)
Efficiency> 88 % (for 230 V AC and nominal values)
Input fuse4 A (slow-blow, internal)
Output power100.8 W
Product typePower supply
Screw threadM3
UL approvalsUL/C-UL listed UL 508
Assembly notealignable: 0 mm horizontally, 30 mm vertically
Mounting typeDIN rail mounting
Climatic class3K3 (in acc. with EN 60721)
Inrush current< 15 A (typical)
Product familySTEP POWER
Status display"DC OK" LED green
Frequency range80 MHz ... 1 GHz
Residual ripple< 40 mVPP(20 MHz)
Type of housingPolycarbonate
Article revision05
Discharge in air± 8 kV (Air discharge)
Horizontal pitch5 Div.
Housing materialPlastic
Number of phases1.00
Protection classII (in closed control cabinet)
Stripping length6.5 mm
Connection methodScrew connection
Contact discharge± 6 kV (Contact discharge)
Control deviation< 1 % (change in load, static 10 % ... 90 %)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Rail applicationsEN 50121-4
AC frequency range45 Hz ... 65 Hz
Frequency range DC0 Hz
Protective circuitTransient surge protection; Varistor
Types of signalingLED
Current consumption1.3 A (120 V AC)
Degree of pollution2
Dimensional drawing
Foot latch materialPOM (Polyoxymethylene)
Input voltage range85 V AC ... 264 V AC
Output current Imax6.5 A
Test field strength10 V/m
Connection in seriesyes
Degree of protectionIP20
Mains buffering timetyp. 20 ms (120 V AC)
Overvoltage categoryIII
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Output characteristicU/I
Shipbuilding approvalDNV GL (EMC B) ABS, NK
Standards/regulationsEN 61000-4-2
Tightening torque max0.6 Nm
Typical response time< 0.5 s
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Connection in parallelyes, for redundancy and increased capacity
Input voltage range AC85 V AC ... 264 V AC
Input voltage range DC95 V DC ... 250 V DC
Nominal output voltage24 V DC
Note on status displayUOUT> 21.5 V: LED lights up
Power factor (cos phi)0.58
Tightening torque, min0.5 Nm
With protective coatingno
Nominal power consumption196.7 VA
Operating voltage displayGreen LED
Standard - Safe isolationDIN VDE 0100-410
MTBF (IEC 61709, SN 29500)> 897000 h (40 °C)
Feedback voltage resistance≤ 35 V DC
Nominal input voltage range100 V AC ... 240 V AC
Nominal output current (IN)4.2 A (-25 °C ... 55 °C)
Power loss nominal load max.13.2 W
Standard - Electrical safetyIEC 62368-1 (SELV)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Inrush current integral (I2t)< 1 A2s
Voltage type of supply voltageAC/DC
Ambient temperature (operation)-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Insulation voltage input/output4 kV AC (type test)
Conductor cross section AWG max.12
Conductor cross section AWG min.24
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom30 mm / 30 mm
SIL in accordance with IEC 615080
Maximum no-load power dissipation< 0.7 W
Standard - Safety of transformersEN 61558-2-16
Conductor cross section, rigid max.2.5 mm²
Conductor cross section, rigid min.0.2 mm²
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise immunityEN 61000-6-1
Peak switching voltages nominal load< 30 mVPP(20 MHz)
Conductor cross section flexible max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60204-1 (PELV)
Depth Device depth (DIN rail mounting)55 mm (Device depth (DIN rail mounting))
Ambient temperature (storage/transport)-40 °C ... 85 °C
Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)
Setting range of the output voltage (USet)22.5 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) class B used in industry and residential area / EMC 1
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) class B used in industry and residential area / EMC 1
Protection against overvoltage at the output (OVP)< 35 V DC
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

Product Description

STEP POWER Primary Switch-On Power Rail Mountable Power Supply, Input: Single Phase, Output: 24 V DC/4.2 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top