Service time: Monday to Friday 9:00-18:00
STEP-PS/ 1AC/12DC/5 - STEP-PS/ 1AC/12DC/5 2868583 PHOENIX CONTACT Power supply unit
In Stock Hot Product

STEP-PS/ 1AC/12DC/5

STEP-PS/ 1AC/12DC/5 2868583 PHOENIX CONTACT Power supply unit

$0.00USD
4372 in stock
Key Specifications
GTIN:4046356310598
Orderkey:2868583
Catalog page:Page 245 (C-4-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356310598
Orderkey2868583
Catalog pagePage 245 (C-4-2017)
Packing unit1 pc
(Input data)< 0.1 % (change in input voltage ±10 %)
(Output data)
Country of originPL (Poland)
Custom tariff number85044030
(Ambient conditions)typ. 120 ms (230 V AC)
Derating (Input data)55 °C ... 70 °C (2.5%/K)
Screw thread (General)M3
Efficiency (Output data)> 87 % (for 230 V AC and nominal values)
Net weight (Output data)0.27 kg
Output power (Input data)60 W
(Connection data, output)15 Hz ... 150 Hz, 2.3g, 90 min.
Stripping length (General)6.5 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Screw connection
Depth (Key Commercial Data)61 mm
Width (Key Commercial Data)72 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)90 mm
Residual ripple (Input data)< 55 mVPP(20 MHz)
Control deviation (Input data)< 1 % (change in load, static 10 % ... 90 %)
Protection class (Output data)II (in closed control cabinet)
Input fuse (Ambient conditions)3.15 A (slow-blow, internal)
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
Shock (Connection data, output)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Degree of pollution (Dimensions)2
Feedback resistance (Input data)≤ 25 V DC
Output current Imax (Input data)9 A
Connection in series (Input data)yes
Degree of protection (Dimensions)IP20
Voltage (Connection data, output)10 V (Test Level 3)
Comments (Connection data, output)Criterion B
Degree of protection (Output data)IP20
Typical response time (Input data)< 0.5 s
Assembly instructions (Output data)alignable: 0 mm horizontally, 30 mm vertically
Connection in parallel (Input data)Yes, for redundancy and increased capacity
Nominal output voltage (Input data)12 V DC ±1 %
Mains buffering (Ambient conditions)typ. 27 ms (120 V AC)
Weight per Piece (excluding packing)310.000 g
Screw thread (Connection data, input)M3
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
UL approvals (Connection data, output)UL/C-UL listed UL 508
AC frequency range (Ambient conditions)45 Hz ... 65 Hz
Frequency range DC (Ambient conditions)0 Hz
Operating voltage display (Output data)Green LED
Type of protection (Ambient conditions)Transient surge protection
Current consumption (Ambient conditions)0.8 A (120 V AC)
Input voltage range (Ambient conditions)85 V AC ... 264 V AC
MTBF (IEC 61709, SN 29500) (Output data)
Noise immunity (Connection data, output)EN 61000-6-2:2005
Nominal output current (IN) (Input data)5 A (-25 °C ... 55 °C)
Frequency range (Connection data, output)0.15 MHz ... 80 MHz
Inrush surge current (Ambient conditions)< 15 A (typical)
Power loss nominal load max. (Input data)8.6 W
Stripping length (Connection data, input)6.5 mm
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Screw connection
Output overvoltage protection (Input data)< 25 V DC
Contact discharge (Connection data, output)4 kV (Test Level 2)
Insulation voltage input / PE (Output data)3.5 kV AC (type test)
Power factor (cos phi) (Ambient conditions)0.56
Rail applications (Connection data, output)EN 50121-4
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Insulation voltage output / PE (Output data)500 V DC (routine test)
Insulation voltage input/output (Output data)4 kV AC (type test)
Test field strength (Connection data, output)3 V/m
Nominal power consumption (Ambient conditions)125 VA
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Low Voltage Directive (Connection data, output)Conformance with LV directive 2006/95/EC
Shipbuilding approval (Connection data, output)DNV GL (EMC B) ABS, NK
Standards/regulations (Connection data, output)EN 61000-4-11
Vibration (operation) (Connection data, output)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Nominal input voltage range (Ambient conditions)100 V AC ... 240 V AC
Peak switching voltages nominal load (Input data)< 55 mVPP(20 MHz)
Protective circuit/component (Ambient conditions)Varistor
Standard - Safe isolation (Connection data, output)DIN VDE 0100-410
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Standard - Electrical safety (Connection data, output)IEC 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Connection data, output)Conformance with EMC Directive 2014/30/EU
Setting range of the output voltage (USet) (Input data)10 V DC ... 16.5 V DC (> 12 V DC, constant capacity restricted)
Choice of suitable circuit breakers (Ambient conditions)6 A ... 16 A (Characteristics B, C, D, K)
Conductor cross section AWG max. (Connection data, input)12
Conductor cross section AWG min. (Connection data, input)24
Connection in acc. with standard (Connection data, output)CUL
Conductor cross section solid max. (Connection data, input)2.5 mm²
Conductor cross section solid min. (Connection data, input)0.2 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)< 0.5 W
Standard - Safety of transformers (Connection data, output)EN 61558-2-16
Conductor cross section flexible max. (Connection data, input)2.5 mm²
Conductor cross section flexible min. (Connection data, input)0.2 mm²
Standard – Safety extra-low voltage (Connection data, output)IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Limitation of mains harmonic currents (Connection data, output)EN 61000-3-2
Information technology equipment - safety (CB scheme) (Connection data, output)CB Scheme
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment (Connection data, output)EN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data, output)EN 50178/VDE 0160 (PELV)

Product Description

STEP POWER primary switch-mode power supply for rail mounting, input: single-phase, output: 12 V DC/5 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top