| Parameter | Value |
|---|---|
| GTIN | 4017918077877 |
| Orderkey | 2826266 |
| (General) | EN 50178 |
| (Coil side) | 36 V DC |
| Catalog page | Page 444 (C-5-2017) |
| Packing unit | 10 pc |
| Country of origin | DE (Germany) |
| Custom tariff number | 85364900 |
| Insulation (General) | Basic insulation |
| (Ambient conditions) | Surge protection Varistor |
| Contact type (Coil side) | Double contact, 1 PDT |
| Depth (Key Commercial Data) | 112 mm |
| Width (Key Commercial Data) | 20.8 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Contact material (Coil side) | Au |
| Height (Key Commercial Data) | 42.5 mm |
| Degree of pollution (General) | 2 |
| Overvoltage category (General) | III |
| Net weight (SAP) (Contact side) | 41.52 g |
| Standards/regulations (General) | IEC 60664 |
| Mounting position (Contact side) | any |
| Maximum inrush current (Coil side) | 0.2 A |
| Type of switch contact (Coil side) | Double contact |
| Weight per Piece (excluding packing) | 41.520 g |
| Maximum switching voltage (Coil side) | 30 V AC |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Mechanical service life (Contact side) | approx. 2x 107cycles |
| Limiting continuous current (Coil side) | 0.5 A |
| Protective circuit (Ambient conditions) | Bridge rectifier Bridge rectifier |
| Typical release time (Ambient conditions) | 8 ms |
| Typical response time (Ambient conditions) | 10 ms |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 50 °C |
| Nominal input voltage UN (Ambient conditions) | 230 V AC |
| Operating voltage display (Ambient conditions) | yes |
| Typical input current at UN (Ambient conditions) | 18 mA |
| Interrupting rating (ohmic load) max. (Coil side) | 5 W (at 24 V DC) |
| Ambient temperature (storage/transport) (Dimensions) | -20 °C ... 70 °C |
| Input voltage range in reference to UN (Ambient conditions) | 0.9 ... 1.1 |
| Power dissipation for nominal condition (Ambient conditions) | 4.14 W |
Technical specifications and performance data