| Parameter | Value |
|---|---|
| Surge protection; Varistor | |
| Depth | 112 mm |
| Width | 20.8 mm |
| Height | 42.5 mm |
| Insulation | Basic insulation |
| Product type | Single relay |
| Mounting type | Plug-in mounting |
| Article revision | 07 |
| Contact material | AgNi |
| Drive (polarity) | polarized |
| Pollution degree | 2 |
| Mounting position | any |
| Drive and function | monostable |
| Protective circuit | Bridge rectifier; Bridge rectifier |
| Input voltage range | 21.6 V AC ... 26.4 V AC (20 °C) |
| Overvoltage category | III |
| Typical release time | 10 ms |
| Standards/regulations | IEC 60664 |
| Typical response time | 8 ms |
| Contact switching type | 1 changeover contact |
| Maximum inrush current | 8 A |
| Type of switch contact | Single contact |
| Mechanical service life | approx. 2x 107cycles |
| Nominal input voltage UN | 24 V AC |
| Maximum switching voltage | 250 V AC/DC |
| Operating voltage display | Yellow LED |
| Limiting continuous current | 6 A |
| Typical input current at UN | 26 mA |
| Date of last data management | 29.05.2024 |
| Test voltage (Winding/contact) | 2.5 kV AC (50 Hz, 1 min., winding/contact) |
| Ambient temperature (operation) | -20 °C ... 50 °C |
| Interrupting rating (ohmic load) max. | 140 W (at 24 V DC) |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Maximum power dissipation for nominal condition | 0.62 W |
Technical specifications and performance data
Installation and operation guide