Service time: Monday to Friday 9:00-18:00
ST 2,5/ 1P - ST 2,5/ 1P 3040012 PHOENIX CONTACT Feed-through terminal block
In Stock Hot Product

ST 2,5/ 1P

ST 2,5/ 1P 3040012 PHOENIX CONTACT Feed-through terminal block

$1.11USD
9041 in stock
Key Specifications
GTIN:4017918832612
Orderkey:3040012
Catalog page:Page 311 (C-1-2017)
Packing unit:50 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918832612
Orderkey3040012
Catalog pagePage 311 (C-1-2017)
Packing unit50 pc
Width (General)5.2 mm
Length (General)48.5 mm
Country of originDE (Germany)
(Connection data)IEC 61984
Custom tariff number85369010
(Key Commercial Data)Plant engineering
Minimum order quantity50 pc
End cover width (General)2.2 mm
Height NS 35/15 (General)44 mm
Height NS 35/7,5 (General)36.5 mm
Color (Key Commercial Data)gray
(Standards and Regulations)No hazardous substances above threshold values
Stripping length (Dimensions)8 mm ... 10 mm
Connection method (Dimensions)Spring-cage/plug-in connection
Setpoint (Key Commercial Data)1 N
ASD level (Key Commercial Data)0.964 (m/s2)2/Hz
Potentials (Key Commercial Data)1
Shock form (Key Commercial Data)Half-sine
Acceleration (Key Commercial Data)5 g
Test spectrum (Key Commercial Data)Service life test category 1, class B, body mounted
Shock duration (Key Commercial Data)30 ms
Test frequency (Key Commercial Data)f1= 5 Hz to f2= 150 Hz
Weight per Piece (excluding packing)5.500 g
Open side panel (Key Commercial Data)Yes
Test directions (Key Commercial Data)X-, Y- and Z-axis (pos. and neg.)
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Internal cylindrical gage (Dimensions)A3
Number of levels (Key Commercial Data)1
Shock test result (Key Commercial Data)Test passed
Nominal current IN (Key Commercial Data)24 A (see derating curve)
Nominal voltage UN (Key Commercial Data)500 V
Short-time current (Key Commercial Data)0.48 kA
Area of application (Key Commercial Data)Railway industry
Degree of pollution (Key Commercial Data)3
Insulating material (Key Commercial Data)PA
Rated surge voltage (Key Commercial Data)6 kV
Maximum load current (Key Commercial Data)24 A (For 4 mm² conductor cross section, se derating curve)
Overvoltage category (Key Commercial Data)III
Tight fit on carrier (Key Commercial Data)NS 35
Nominal cross section (Key Commercial Data)2.5 mm²
Number of connections (Key Commercial Data)2
Result of thermal test (Key Commercial Data)Test passed
Test duration per axis (Key Commercial Data)5 h
Conductor cross section AWG max. (Dimensions)12
Conductor cross section AWG min. (Dimensions)28
Connection in acc. with standard (Dimensions)IEC 61984
Conductor cross section solid max. (Dimensions)4 mm²
Conductor cross section solid min. (Dimensions)0.08 mm²
Insulating material group (Key Commercial Data)I
Surge voltage test setpoint (Key Commercial Data)7.3 kV
Conductor cross section flexible max. (Dimensions)2.5 mm²
Conductor cross section flexible min. (Dimensions)0.08 mm²
Connection in acc. with standard (Connection data)CSA
Result of surge voltage test (Key Commercial Data)Test passed
Ambient temperature (assembly) (Key Commercial Data)-40 °C ... 100 °C
NF F16-101, NF F10-102 Class F (Key Commercial Data)2
NF F16-101, NF F10-102 Class I (Key Commercial Data)2
Number of shocks per direction (Key Commercial Data)3
Result of tight fit on support (Key Commercial Data)Test passed
Short circuit stability result (Key Commercial Data)Test passed
Test specification, shock test (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Ambient temperature (operation) (Key Commercial Data)-50 °C (see derating curve)
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data)>32 %
Max. AWG conductor cross section, flexible (Dimensions)14
Min. AWG conductor cross section, flexible (Dimensions)28
Flammability rating according to UL 94 (Connection data)V0
Flame test method (DIN EN 60695-11-10) (Key Commercial Data)V0
Flammability rating according to UL 94 (Key Commercial Data)V0
Insertion/withdrawal cycles mechanical (Key Commercial Data)100
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data)passed
Oscillation, broadband noise test result (Key Commercial Data)Test passed
Power frequency withstand voltage setpoint (Key Commercial Data)1.89 kV
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data)passed
Conductor cross section short circuit testing (Key Commercial Data)4 mm²
Static insulating material application in cold (Key Commercial Data)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data)Test passed
Maximum power dissipation for nominal condition (Key Commercial Data)0.77 W
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data)27,5 MJ/kg
Result of power-frequency withstand voltage test (Key Commercial Data)Test passed
Test specification, oscillation, broadband noise (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data)passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions)2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions)0.14 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data)130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions)2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions)0.14 mm²
Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data)30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data)125 °C
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions)0.5 mm²

Product Description

Feed-through terminal, nominal voltage: 500 V, nominal current: 24 A, number of connections: 2, connection type: Spring connection / plug-in connection, 1st floor, left-hand connection, Dimensioning c
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top