| Parameter | Value |
|---|---|
| 1201044 E/1 | |
| Color | ivory (RAL 1014) |
| Width | 15.3 mm |
| Height | 53 mm |
| Result | Test passed |
| output | (Permanent) |
| Material | Ceramics |
| Potentials | 1 |
| Bridge data | 100 A / 35 mm² |
| Product type | High temperature terminal block |
| Screw thread | M6 |
| Torque range | 3.2 Nm ... 3.7 Nm |
| Mounting type | NS 32 |
| Rated current | 101 A |
| Rated voltage | 550 V |
| Identification | II 2 GD Ex eb IIC Gb |
| Number of rows | 1 |
| Depth on NS 32 | 67 mm |
| List of bridges | / KB- 15 / 0204259 |
| Nominal current | 101 A (with 25 mm² conductor cross section) |
| Nominal voltage | 800 V |
| Open side panel | Yes |
| Article revision | 07 |
| Stripping length | 16 mm |
| Time of exposure | 30 s |
| Cross section AWG | 18 ... 2 (converted acc. to IEC) |
| Tightening torque | 3.2 ... 3.7 Nm |
| Contact resistance | 0.2 mΩ |
| Degree of pollution | 3 |
| Rated surge voltage | 8 kV |
| Maximum load current | 125 A (with 35 mm² conductor cross section) |
| Overvoltage category | III |
| Nominal cross section | 35 mm² |
| Number of connections | 2 |
| Test voltage setpoint | 2 kV |
| Connection capacity AWG | 18 ... 2 |
| DIN rail/fixing support | NS 32 |
| Ex temperature increase | 40 K (116.5 A / 25 mm²) |
| Rated cross section AWG | 3 |
| Ex-certified accessories | 0205067 D-SSK 135 KER |
| Rated insulation voltage | 500 V |
| for bridging with bridge | 550 V |
| Connection capacity rigid | 1 mm² ... 35 mm² |
| Insulating material group | I |
| Internal cylindrical gage | B7 |
| Operating temperature range | -60 °C ... 180 °C |
| Connection capacity flexible | 1 mm² ... 25 mm² |
| Conductor cross section rigid | 1 mm² ... 35 mm² |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Ambient temperature (operation) | -60 °C ... 180 °C |
| Number of connections per level | 2 |
| Conductor cross section flexible | 1 mm² ... 25 mm² |
| Connection in acc. with standard | IEC 60947-7-1 |
| Permissible humidity (operation) | 20 % ... 90 % |
| Requirement temperature-rise test | Increase in temperature ≤ 45 K |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Conductor cross section, flexible [AWG] | 18 ... 4 (converted acc. to IEC) |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| 2 conductors with same cross section, solid | 0.75 mm² ... 10 mm² |
| 2 conductors with same cross section, flexible | 0.75 mm² ... 10 mm² |
| Maximum power dissipation for nominal condition | 4.06 W |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.75 mm² ... 16 mm² |
| Relative insulation material temperature index (Elec., UL 746 B) | 1000 °C |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.75 mm² ... 25 mm² |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.75 mm² ... 10 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.75 mm² ... 10 mm² |
Technical specifications and performance data
Installation and operation guide