Key Specifications
:1201044 E/1
Color:ivory (RAL 1014)
Width:10.4 mm
Result:Test passed
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
1201044 E/1
Colorivory (RAL 1014)
Width10.4 mm
ResultTest passed
output(Permanent)
MaterialCeramics
SpectrumService life test category 1, class B, body mounted
ASD level1.857 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 150 Hz
Potentials1
Bridge data55 A / 10 mm²
Pulse shapeHalf-sine
Revolutions135
Acceleration0.8g
Product typeHigh temperature terminal block
Screw threadM4
Torque range1.5 Nm ... 1.8 Nm
Mounting typeNS 32
Rated current55 A
Rated voltage440 V
SpecificationDIN EN 50155 (VDE 0115-200):2008-03
Identification II 2 GD Ex eb IIC Gb
Number of rows1
Rotation speed10 rpm
Shock duration30 ms
End cover width4 mm
List of bridgesChain bridge / KB- 10 / 0203205
Nominal current57 A
Nominal voltage630 V (up to 800 V with a conductor cross section of 16 mm²)
Open side panelYes
Test directionsX-, Y- and Z-axis
Article revision05
Stripping length11 mm
Time of exposure30 s
Cross section AWG20 ... 6 (converted acc. to IEC)
Tightening torque1.5 ... 1.8 Nm
Contact resistance0.23 mΩ
Degree of pollution3
Rated surge voltage8 kV
Test force setpoint5 N
Maximum load current76 A (with 16 mm² conductor cross section)
Overvoltage categoryIII
Nominal cross section10 mm²
Number of connections2
Test voltage setpoint9.8 kV
Test duration per axis5 h
Connection capacity AWG20 ... 6
DIN rail/fixing supportNS 32
Ex temperature increase40 K (60.9 A / 10 mm²)
Rated cross section AWG8
Ex-certified accessories0203069 D-SSK 116 KER
Rated insulation voltage400 V
for bridging with bridge440 V
Connection capacity rigid0.5 mm² ... 16 mm²
Insulating material groupI
Internal cylindrical gageB6
Operating temperature range-60 °C ... 180 °C
Connection capacity flexible0.5 mm² ... 10 mm²
Conductor cross section rigid0.5 mm² ... 16 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Conductor cross section/weight0.5 mm² / 0.3 kg
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 180 °C
Number of connections per level2
Conductor cross section flexible0.5 mm² ... 10 mm²
Connection in acc. with standardIEC 60947-7-1
Permissible humidity (operation)20 % ... 90 %
Requirement temperature-rise testIncrease in temperature ≤ 45 K
Short-time withstand current 10 mm²1.2 kA
Short-time withstand current 16 mm²1.92 kA
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG]20 ... 8 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
2 conductors with same cross section, solid0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible0.5 mm² ... 4 mm²
Maximum power dissipation for nominal condition1.82 W
Flexible conductor cross section (ferrule with plastic sleeve)0.5 mm² ... 6 mm²
Relative insulation material temperature index (Elec., UL 746 B)1000 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.5 mm² ... 10 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.5 mm² ... 4 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 6 mm²

Product Description

Pass terminal, connection type: screw connection, section: 0.5 mm² - 16 mm², AWG 20 - 6, width: 10.4 mm, colour: white, mounting type: NS 32, insulation material: ceramic
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top