| Parameter | Value |
|---|---|
| 1201044 E/1 | |
| Color | ivory (RAL 1014) |
| Width | 10.4 mm |
| Result | Test passed |
| output | (Permanent) |
| Material | Ceramics |
| Spectrum | Service life test category 1, class B, body mounted |
| ASD level | 1.857 (m/s²)²/Hz |
| Frequency | f1= 5 Hz to f2= 150 Hz |
| Potentials | 1 |
| Bridge data | 55 A / 10 mm² |
| Pulse shape | Half-sine |
| Revolutions | 135 |
| Acceleration | 0.8g |
| Product type | High temperature terminal block |
| Screw thread | M4 |
| Torque range | 1.5 Nm ... 1.8 Nm |
| Mounting type | NS 32 |
| Rated current | 55 A |
| Rated voltage | 440 V |
| Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
| Identification | II 2 GD Ex eb IIC Gb |
| Number of rows | 1 |
| Rotation speed | 10 rpm |
| Shock duration | 30 ms |
| End cover width | 4 mm |
| List of bridges | Chain bridge / KB- 10 / 0203205 |
| Nominal current | 57 A |
| Nominal voltage | 630 V (up to 800 V with a conductor cross section of 16 mm²) |
| Open side panel | Yes |
| Test directions | X-, Y- and Z-axis |
| Article revision | 05 |
| Stripping length | 11 mm |
| Time of exposure | 30 s |
| Cross section AWG | 20 ... 6 (converted acc. to IEC) |
| Tightening torque | 1.5 ... 1.8 Nm |
| Contact resistance | 0.23 mΩ |
| Degree of pollution | 3 |
| Rated surge voltage | 8 kV |
| Test force setpoint | 5 N |
| Maximum load current | 76 A (with 16 mm² conductor cross section) |
| Overvoltage category | III |
| Nominal cross section | 10 mm² |
| Number of connections | 2 |
| Test voltage setpoint | 9.8 kV |
| Test duration per axis | 5 h |
| Connection capacity AWG | 20 ... 6 |
| DIN rail/fixing support | NS 32 |
| Ex temperature increase | 40 K (60.9 A / 10 mm²) |
| Rated cross section AWG | 8 |
| Ex-certified accessories | 0203069 D-SSK 116 KER |
| Rated insulation voltage | 400 V |
| for bridging with bridge | 440 V |
| Connection capacity rigid | 0.5 mm² ... 16 mm² |
| Insulating material group | I |
| Internal cylindrical gage | B6 |
| Operating temperature range | -60 °C ... 180 °C |
| Connection capacity flexible | 0.5 mm² ... 10 mm² |
| Conductor cross section rigid | 0.5 mm² ... 16 mm² |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Conductor cross section/weight | 0.5 mm² / 0.3 kg |
| Number of shocks per direction | 3 |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Ambient temperature (operation) | -60 °C ... 180 °C |
| Number of connections per level | 2 |
| Conductor cross section flexible | 0.5 mm² ... 10 mm² |
| Connection in acc. with standard | IEC 60947-7-1 |
| Permissible humidity (operation) | 20 % ... 90 % |
| Requirement temperature-rise test | Increase in temperature ≤ 45 K |
| Short-time withstand current 10 mm² | 1.2 kA |
| Short-time withstand current 16 mm² | 1.92 kA |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Conductor cross section, flexible [AWG] | 20 ... 8 (converted acc. to IEC) |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| 2 conductors with same cross section, solid | 0.5 mm² ... 4 mm² |
| 2 conductors with same cross section, flexible | 0.5 mm² ... 4 mm² |
| Maximum power dissipation for nominal condition | 1.82 W |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.5 mm² ... 6 mm² |
| Relative insulation material temperature index (Elec., UL 746 B) | 1000 °C |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.5 mm² ... 10 mm² |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.5 mm² ... 4 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 6 mm² |
Technical specifications and performance data
Installation and operation guide