Key Specifications
Color:gray (RAL 7042)
Depth:41.5 mm
Pitch:6.2 mm
Width:80.6 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Colorgray (RAL 7042)
Depth41.5 mm
Pitch6.2 mm
Width80.6 mm
Height21 mm
Length21 mm
ResultTest passed
SpectrumService life test category 1, class B, body mounted
ASD level0.964 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 150 Hz
Pulse shapeHalf-sine
Acceleration0.58g
Product typeTerminal plug
SpecificationDIN EN 50155 (VDE 0115-200):2018-05
Shock duration30 ms
Nominal current32 A
Nominal voltage800 V
Test directionsX-, Y- and Z-axis
Article revision03
Stripping length8 mm ... 10 mm
Time of exposure30 s
Cross section AWG28 ... 10 (converted acc. to IEC)
Degree of pollution3
Insulating materialPA
Number of positions13
Rated surge voltage8 kV
Maximum load current32 A (with 6 mm² conductor cross section)
Overvoltage categoryIII
Nominal cross section4 mm²
Test voltage setpoint2 kV
Test duration per axis5 h
Insulating material groupI
Internal cylindrical gageA4
Conductor cross section rigid0.08 mm² ... 6 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C (max. operating temperature see derating curve)
Conductor cross section flexible0.08 mm² ... 4 mm²
Connection in acc. with standardIEC 61984
Permissible humidity (operation)20 % ... 90 %
Short-time withstand current 4 mm²0.48 kA
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG]28 ... 12 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
Static insulating material application in cold-60 °C
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 4 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 4 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1 mm²

Product Description