| Parameter | Value |
|---|---|
| GTIN | 4055626314785 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2403683 |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| Custom tariff number | 85363090 |
| Weight (Cable entry) | approx. 30 kg |
| String fuse (Monitoring) | Midget / 10.3 x 38 Not included in the scope of supply |
| Impact strength (Cable entry) | IK08 |
| Protection class (Cable entry) | II |
| Protection level Up (Monitoring) | ≤ 2.5 kV |
| Data interface (System parameter) | 1x Modbus/RTU (RS-485) |
| Material cover/door (Cable entry) | |
| Supply voltage (System parameter) | 24 V DC (nominal) |
| Degree of protection (Cable entry) | IP65 |
| Installation location (Cable entry) | Outdoor installation, covered area |
| Connection method (Safety equipment) | SUNCLIX PV connector |
| IEC test classification (Monitoring) | I / II |
| Surge protective device (Monitoring) | T1 / T2 |
| System voltage (Key Commercial Data) | 1000 V DC (Umax) |
| Weight per Piece (excluding packing) | 22,220.000 g |
| Sealing area output (Safety equipment) | 3.5 mm ... 6 mm |
| Type of cable entry (Safety equipment) | Cable gland |
| Number of outputs (Key Commercial Data) | 1 (per MPP tracker) |
| Switching capacity (Key Commercial Data) | max. 250 A (1000 V DC) |
| Sealing area grounding (Safety equipment) | 5 mm ... 10 mm |
| Sealing area data cable (Safety equipment) | 3.5 mm ... 6 mm |
| Standards/regulations (Ambient conditions) | IEC 61439 |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 55 °C |
| Sealing area string input (Safety equipment) | 3.5 mm ... 6 mm |
| Cable cross section output (Safety equipment) | 6 mm² |
| Number of string inputs (Key Commercial Data) | 32 |
| Number of measuring channels (System parameter) | 16 |
| Cable cross section grounding (Safety equipment) | 16 mm² |
| Cable cross section data cable (Safety equipment) | 1.5 mm² |
| Data transmission protective circuit (Monitoring) | 24 V DC |
| Cable cross section string input (Safety equipment) | 6 mm² |
| Voltage measurement output signal (System parameter) | 2 V ... 10 V (Analog) |
| Outer dimensions: width, height, depth (General data) | 535 mm x 735 mm x 270 mm (Housing dimensions) |
| Total discharge current Itotal(8/20) µs (Monitoring) | 40 kA |
| Total discharge current Itotal(10/350) µs (Monitoring) | 5 kA |
Technical specifications and performance data