| Parameter | Value |
|---|---|
| Link | Screw connection with cage |
| Step | 3.81 mm |
| note | Complies with WEEE/RoHS, no thread-like materials according to IEC 60068-2-82/JEDEC JESD 201 |
| type | Block of terminal blocks for printed circuit boards |
| Packaging | Packed in carton |
| Width [w] | 7.61 mm |
| Height [h] | 13 mm |
| Length [l] | 10 mm |
| Pin Layout | Linear Pinning |
| Shank sizes | 0.5 x 0.9 mm |
| Color (Case) | Green (6021) |
| Note for use | A predefined tightening torque must always be observed for secure connection. Especially in the case of two- and three-pole PCB terminals, the single contact soldering tip may not block them. For this reason, the terminals must be reinforced when connecting (fixed by hand, reinforcement on the housing). |
| Product Line | COMBICON Terminals S |
| Product Type | PCB terminal block |
| Bore diameter | 1.1 mm |
| Mounting type | Wave Soldering |
| Article review | 03 |
| Number of rows | 1 |
| Product Family | SMKDS 1 |
| Surface Finish | Galvanic tin plating |
| Number of poles | 2 |
| Contact Material | Cu Alloy |
| Rated Current IN | 10 A |
| Rated voltage UN | 200 V |
| Tightening torque | 0.22 Nm ... 0.25 Nm |
| Test Specification | DIN EN 60947-1 (VDE 0660-100):2015-09 |
| Dimensioned Drawing | |
| Installation Height | 9.5 mm |
| Insulation material | PA |
| Nominal cross-section | 1 mm² |
| Sizing voltage (II/2) | 400 V |
| Weld Shank Length [P] | 3.5 mm |
| Sizing voltage (III/2) | 200 V |
| Sizing voltage (III/3) | 160 V |
| Appliance type screw head | Longitudinal slit (L) |
| Insulation Material Group | The |
| CTI according to IEC 60112 | 600 |
| Conductor cross-section AWG | 26 ... 16 |
| Rated Impulse Voltage (II/2) | 2.5 kV |
| Minimum creepage value (II/2) | 2 mm |
| Rated impulse voltage (III/2) | 2.5 kV |
| Rated impulse voltage (III/3) | 2.5 kV |
| Rigid conductor cross-section | 0.14 mm² ... 1.5 mm² |
| Sizing Impulse Voltage (II/2) | 2.5 kV |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Minimum creepage value (III/2) | 1.5 mm |
| Minimum creepage value (III/3) | 2 mm |
| Rated Isolation Voltage (II/2) | 400 V |
| Sizing Impulse Voltage (III/2) | 2.5 kV |
| Sizing impulse voltage (III/3) | 2.5 kV |
| Ambient temperature (operating) | -40 °C ... 100 °C (Depending on current flow curve/derating curve) |
| Rated Isolation Voltage (III/2) | 200 V |
| Flexible conductor cross-section | 0.14 mm² ... 1 mm² |
| Rated insulation voltage (III/3) | 160 V |
| Length of the section to be stripped | 5 mm |
| Number of Welding Pins per Potential | 1 |
| Metal Surface Weld Area (Middle Layer) | Nickel (2 - 3 μm Ni) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Combustibility class according to UL 94 | V0 |
| Relative humidity (transport and storage) | 30 % ... 70 % |
| Metal Surface Welding Area (Surface Layer) | Tin (5 - 7 μm Sn) |
| Metal surface connection point (middle layer) | Nickel (2 - 3 μm Ni) |
| 2 conductors of identical cross-section, rigid | 0.14 mm² ... 0.5 mm² |
| Metal Surface, Connection Point (Surface Layer) | Tin (5 - 7 μm Sn) |
| 2 conductors of identical flexible cross-section | 0.14 mm² ... 0.2 mm² |
| Minimum creepage value - inhomogeneous range (II/2) | 1.5 mm |
| Minimum creepage value - inhomogeneous range (III/2) | 1.5 mm |
| Minimum clearance value - inhomogeneous range (III/3) | 1.5 mm |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Brinell hardness test temperature according to EN 60695-10-2 | 125 °C |
| GWIT filament ignition temperature according to EN 60695-2-13 | 775 |
| Flammability index of GWFI filament according to EN 60695-2-12 | 850 |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.25 mm² ... 0.5 mm² |
| Flexible conductor cross-section with cable lug without plastic collar | 0.25 mm² ... 0.5 mm² |
Technical specifications and performance data
Installation and operation guide