| Parameter | Value |
|---|---|
| GTIN | 4017918054113 |
| Orderkey | 2271073 |
| Catalog page | Page 556 (C-7-2013) |
| Packing unit | 10 pc |
| Country of origin | DE (Germany) |
| Custom tariff number | 85364190 |
| Depth (Key Commercial Data) | 25 mm |
| Output circuit (Input data) | 2-wire, floating |
| Width (Key Commercial Data) | 13 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 29 mm |
| Operating mode (Output data) | 100% operating factor |
| Mounting position (Output data) | any |
| Standards/regulations (General) | DIN VDE 0110 |
| Type of protection (Input data) | Reverse polarity protection |
| Output voltage range (Input data) | 8 V DC ... 48 V DC |
| Assembly instructions (Output data) | Can be aligned with 2 mm spacing |
| Standards/regulations (Output data) | DIN VDE 0110 |
| Weight per Piece (excluding packing) | 17.150 g |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Test voltage input/output (Output data) | 2.5 kV (50 Hz, 1 min.) |
| Type of protection (Ambient conditions) | Reverse polarity protection |
| Input voltage range (Ambient conditions) | 21.6 V DC ... 26.4 V DC |
| Limiting continuous current (Input data) | 100 mA |
| Protective circuit/component (Input data) | Polarity protection diode |
| Transmission frequency (Ambient conditions) | 600 Hz |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 50 °C |
| Nominal input voltage UN (Ambient conditions) | 24 V DC |
| Typical input current at UN (Ambient conditions) | 5.1 mA |
| Protective circuit/component (Ambient conditions) | Polarity protection diode |
| Ambient temperature (storage/transport) (Dimensions) | -20 °C ... 70 °C |
| Input voltage range in reference to UN (Ambient conditions) | 0.9 ... 1.1 |
| Voltage drop at max. limiting continuous current (Input data) | 1 V |
| Switching threshold "0" signal in reference to UN (Ambient conditions) | ≤ 0.4 |
| Switching threshold "1" signal in reference to UN (Ambient conditions) | ≥ 0.8 |
Technical specifications and performance data
Installation and operation guide