Service time: Monday to Friday 9:00-18:00
SFC14EX - SFC14EX SF-C14EX PANASONIC Safety sensor accessory
In Stock Hot Product

SFC14EX

SFC14EX SF-C14EX PANASONIC Safety sensor accessory

$0.00USD
3551 in stock
Key Specifications
Item:Specifications
PFHD:1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD:100 years or more(Note:Mean time to dangerous failure (in years))
Weight:Net weight: 250 g approx.
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
PFHD1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD100 years or more(Note:Mean time to dangerous failure (in years))
WeightNet weight: 250 g approx.
DetailsApplicantion expansion unit for the SF4B series
ProductExclusive Control Unit for Safety Light Curtain
MaterialEnclosure: ABS
Part NumberSF-C14EX
Product nameExclusive Control Unit for Safety Light Curtain SF-C10
Power voltage24 V DC plus or minus 10 % Ripple P-P 10 % or less
Product NumberSF-C14EX
Ambient humidity30 to 85 % RH, Storage: 30 to 95 % RH
Control categoryISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Shock resistance30 G acceleration in X, Y and Z directions three times each
Muting lamp outputApplicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
Ambient temperature-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉
Connection terminalDetachable spring-cage terminal
Current consumption0.2 A or less (Excluding Safety light curtain and other external connecting device)
Vibration resistance10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each
Insulation resistance20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Applicable standards:JapanJIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe)
CE marking directive complianceMachinery Directive, EMC Directive, RoHS Directive
Applicable standards:Europe (EU)EN 55011, EN ISO 13849-1 (Category 4, PLe)
Connectable safety light curtainsSF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.)
Applicable standards:North AmericaANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Muting lamp output:Protection circuitIncorporated
Applicable standards:International standardIEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe)
Environmental resistance:Degree of protectionEnclosure: IP40Terminal: IP20
Environmental resistance:Dielectric strength voltage1,000 V AC for one min. between all supply terminals connected together and enclosure
Safety outputs(Safety output 1, Safety output 2, Safety output 3)PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current)
Safety outputs(Safety output 1, Safety output 2, Safety output 3):Response timeOFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3.
Auxiliary outputs(Auxiliary output 1, Auxiliary output 2, Auxiliary output 3, Auxiliary output 4)PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current)
Safety outputs(Safety output 1, Safety output 2, Safety output 3):Operation mode(Output operation)Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid
Safety outputs(Safety output 1, Safety output 2, Safety output 3):Protection circuit(Short-circuit protection)Incorporated
Auxiliary outputs(Auxiliary output 1, Auxiliary output 2, Auxiliary output 3, Auxiliary output 4):Operation mode(Output operation)Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.)
Auxiliary outputs(Auxiliary output 1, Auxiliary output 2, Auxiliary output 3, Auxiliary output 4):Protection circuit(Short-circuit protection)Incorporated

Product Description

SF-C14EX_Exclusive Control Unit for Safety Light Curtain_Exclusive Control Unit for Safety Light Curtain SF-C10_Applicantion expansion unit for the SF4B series
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top