Service time: Monday to Friday 9:00-18:00
SF4D-H80-01 - SF4D-H80-01 PANASONIC Compact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D
In Stock Hot Product

SF4D-H80-01

SF4D-H80-01 PANASONIC Compact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D

$0.00USD
4436 in stock
Key Specifications
Item:Specifications
PFHD:3.69×10-9
MTTFD:318 years or more
Remark:Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years).
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
PFHD3.69×10-9
MTTFD318 years or more
RemarkWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.PFHD: Probability of Dangerous Failure per Hour, MTTFD: Mean Time to Dangerous Failure (in years).
DetailsMin. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch)
ProductSafety Light Curtain [Type 4 PLe SIL3]
MaterialEnclosure : Aluminum, Detection surface : Polycarbonate resin and stainless steel (SUS304), Upper cap / lower cap : Nylon
AccessoriesSF4B-TR25 (test rod) : 1 pc.
Part NumberSF4D-H80-01
Product nameCompact & Robust Safety Light Curtain [Type 4 PLe SIL3] SF4D
Safety stateControl output (OSSD 1 / 2) OFF state
Power voltage24 V DC+20-30 %Ripple P-P 10 % or less (excluding voltage drop due to cable)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline.
Product NumberSF4D-H80-01
Subsystem typeType B (IEC 61508-2)
Cable extensionTotal length of emitter / receiver can be extended up to 70 m229.659 fteach using optional mating cable (including the lengthof series mating cables)(Note): In consideration of the voltage drop caused by the cable, use Control output (OSSD 1, OSSD 2) source / sink current and cable length as a guideline.
Muting functionIncorporated (12-core cable)
Operating rangeShort mode : 0.2 to 9 m0.656 to 29.528 ftLong mode : 0.8 to 15 m2.625 to 49.213 ft(selectable by DIP switch)(Note): The operating range is the possible setting distance between the emitter and the receiver.
Ambient humidity30 to 85 % RH, Storage : 30 to 95 % RH
Emitting elementInfrared LED (peak emission wavelength : 850 nm0.0335 mil)
Pollution degree3
Shock resistance300 m/s2acceleration (30 G approx.) in X, Y, and Z directions three times eachMalfunction resistance 100 m/s2acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each
Connecting methodBy connector
Override functionIncorporated (12-core cable)
Protective height1,590 mm62.598 in(Note): When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height.
Interlock functionIncorporated [Manual reset / auto reset (selectable by wiring)] (8-core cable or 12-core cable)
Operating altitude2,000 m6,561.68 ftor less(Note): Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
Optional functionsOptional functions cannot be used when SF4D-□-01 is used.
Ambient illuminanceIncandescent light : 5,000 ℓx or less at the light-receiving surface
Ambient temperature-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage : -25 to +60 ℃-13 to +140 ℉
Current consumptionEmitter : 120 mA or lessReceiver : 150 mA or less
Min. sensing objectø25 mmø0.984 inopaque object(Note): When the floating blanking function is used, the size of the minimum sensing object varies. For the detail, refer to the section on Safety distance.
Power save functionIncorporated
Test input functionIncorporated
No. of beam channels80
Vibration resistance10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions for two hours eachMalfunction resistance 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions twenty times each
Failure response timeWithin response time (OFF response)
Insulation resistance20 MΩ, or more, with 500 V DC megger, between all supply terminals connected together and enclosure
Synchronization methodLine synchronization / optical synchronization (selectable by DIP switch)
Effective aperture angle±2.5° or less at a sensing range of 3 m9.843 ftor longer (based on IEC 61496-2)
Lockout release functionIncorporated
T1 (proof test interval)20 years
Applicable standards:JapanJIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
SFF (Safe Failure Fraction)99%
Application indicator functionIncorporated (only the receiver lights up when optical synchronization is used)
HFT (Hardware Fault Tolerance)1
Applicable standards:China (GB)GB/T 4584
CE marking directive complianceMachinery Directive, EMC Directive, RoHS Directive
Applicable standards:Europe (EU)EN 61496-1/2 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 55011, EN 61000-6-2, EN 50178
Control outputs (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 350 mA・Applied voltage : Same as supply voltage(between control output and +V)・Residual voltage : 2 V or less (source current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less<NPN output selected>・Maximum sink current : 350 mA・Applied voltage : Same as supply voltage(between control output and 0 V)・Residual voltage : 2 V or less (sink current 350 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)・Maximum load capacity : 2.2 μF・Load wiring resistance : 3 Ω or less
Interference prevention function<Not connected in series/parallel>・Line synchronization : 2 units or less (auto)・Optical synchronization : 2 units or less (selectable by DIP switch)<Connected in series/parallel>・Series connection : 5 units or less (total number of beam channels 256 or less)・Parallel connection : 3 units or less (total number of beam channels 192 or less)(Note)・Series / parallel connection mixed : 5 units or less (total number of beam channels 144 or less)(Note)(Note): Note that the setting cannot be changed when SF4D-□-01 is used.
Applicable standards:North AmericaANSI/UL 61496-1/2 (Type 4),CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2
External device monitoring functionIncorporated (8-core cable or 12-core cable)
Weight(Total of emitter and receiver)4,000g approx.
Auxiliary output (AUX)(Non-safety output)PNP open-collector transistor / NPN open collector transistor (selectable)<PNP output selected>・Maximum source current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and +V)・Residual voltage : 2 V or less (source current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)<NPN output selected>・Maximum sink current : 60 mA・Applied voltage : Same as supply voltage(between auxiliary output and 0 V)・Residual voltage : 2 V or less (sink current 60 mA)(excluding voltage drop due to cable)・Leakage current : 0.2 mA or less (including power OFF state)
Applicable standards:International standardIEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
Control output(OSSD 1, OSSD 2):Response timeOFF response : 10 ms or less (Not connected in series / parallel), 18 ms or less (Connected in series / parallel)(Note 1)ON response : 50 ms or less (Note 2)(Note 3)(Note 1): For response times by number of beams, refer to the Control output (OSSD 1, OSSD 2) OFF response times.(Note 2): Because the control output (OSSD 1, OSSD 2) must be OFF for at least 80 ms, the ON response will be delayed more than 50 ms when the light blocked time is less than 30 ms.(Note 3): When optical synchronization is selected, if the beam axes of both the top end and bottom end are blocked, the ON response speed decreases by as much as 1 sec.
Environmental resistance:Degree of protectionIP67, IP65 (IEC), NEMA Type 13 (NEMA 250)
Control outputs (OSSD 1, OSSD 2):Operation modeON when all beams are received, OFF when one or more beams are blocked(Also OFF when internal sensor error or synchronization signal error occurs)(Note): Note that the setting cannot be changed when SF4D-□-01 is used.
Control outputs(OSSD1, OSSD2):Protection circuitIncorporated
Environmental resistance:Dielectric strength voltage1,000 V AC for one minute, between all supply terminals connected together and enclosure
Auxiliary output (AUX)(Non-safety output) : Response timeOFF response : 60 ms or less, ON response : 60 ms or less
Auxiliary output (AUX)(Non-safety output) : Operation modeControl output ON : OFF, Control output OFF : ON(Note): Note that the setting cannot be changed when SF4D-□-01 is used.
Auxiliary output (AUX)(Non-safety output) : Protection circuitIncorporated
Protective height : When using as safety equipment for Chinese press machine or when using for Japanese press machine or paper shearing machine1,580 mm62.205 in(Note): When using as a safety device for a press machine in China or when using SF4D-□-01 as a safety device for a press machine or paper shearing machine in Japan, the length from the center of the first beam channel to the center of the last beam channel become to be protective height.

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top