Service time: Monday to Friday 9:00-18:00
SF4C-H8-J05 - SF4C-H8-J05 PANASONIC Ultra-slim Safety Light Curtain Typ4 (PLe SIL3), Hand Protection, protective height 16..
In Stock Hot Product

SF4C-H8-J05

SF4C-H8-J05 PANASONIC Ultra-slim Safety Light Curtain Typ4 (PLe SIL3), Hand Protection, protective height 16..

$0.00USD
4418 in stock
Key Specifications
Item:Specifications
PFHD:1.66 × 10-9
Cable:0.15 mm212-core heat-resistant PVC cable, 0.5 m1.640 ftlong with connector
MTTFD:100 years or more
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
PFHD1.66 × 10-9
Cable0.15 mm212-core heat-resistant PVC cable, 0.5 m1.640 ftlong with connector
MTTFD100 years or more
DetailsMin. sensing object ø25 mmø0.984 intype (20 mm0.787 inbeam pitch) [Pigtailed type]
ProductUltra-slim Safety Light Curtain [Type 4 PLe SIL3]
MaterialEnclosure: Polycarbonate alloySensing surface: Polycarbonate alloy
Beam pitch20 mm0.787 in
AccessoriesMS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR25 (Test rod): 1 No.
Part NumberSF4C-H8-J05
Product nameUltra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C
ELCA functionIncorporated (reducing mutual interference automatically)
Power voltage24 V DC +10-15 % Ripple P-P 10 % or less
Response timeOFF response: 7 ms or lessON response: 90 ms or less
Product NumberSF4C-H8-J05
Cable extensionExtension up to 40.5 m132.874 ftis possible for both emitter and receiver, with 0.2 mm2or more cable.(Note) When the muting lamp is used, the cable can be extended within 30.5 m100.066 ft(for emitter / receiver).
Muting functionIncorporated
Operating range0.1 to 3 m0.328 to 9.843 ft(Note) The operating range is the possible setting distance between the emitter and the receiver.
Ambient humidity30 to 85 % RH, Storage: 30 to 85 % RH
Emitting elementInfrared LED (Peak emission wavelength: 855 nm0.034 mil)
Pollution degree3
Shock resistance300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each
Override functionIncorporated
Protective height160 mm6.299 in
Interlock functionIncorporated [Manual reset / Automatic reset (Note)](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Operating altitude2,000 m6,561 68 ftor less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
Optional functionsFixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting(Note) In case of using optional function, the handy-controller SFC-HC is required.
Ambient illuminanceIncandescent light: 5,000 lx or less at the light-receiving face
Ambient temperature-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉
Min. sensing objectø25 mmø0.984 inopaque object(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
No. of beam channels8
Vibration resistance10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each
Insulation resistance20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Safety input functionIncorporated (safety contact)
Effective aperture angleplus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)]
Applicable standards:JapanJIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL 3)
Test / reset input functionIncorporated
Applicable standards:Europe (EU)EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
Control outputs (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 200 mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less[When selecting NPN output]- Max. sink current: 200 mA- Applied voltage: same as supply voltage (between the control output and 0 V)- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less
Applicable standards:North AmericaANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
External device monitoring functionIncorporated
Auxiliary output (Non-safety output)PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and +V)- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m32.808 ftlength cable)[When selecting NPN output]- Max. sink current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m32.808 ftlength cable)
Net weight (Total of emitter and receiver)240 g approx.
Applicable standards:International standardIEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3)
Environmental resistance:Degree of protectionIP67 / IP65 (IEC)
Control outputs (OSSD 1, OSSD 2):Operation modeON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.(Note) In case the blanking function is valid, the operation mode is changed.
Control outputs(OSSD1, OSSD2):Protection circuitIncorporated
Auxiliary output (Non-safety output):Operation modeOFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Environmental resistance:Dielectric strength voltage1,000 V AC for one min. between all supply terminals connected together and enclosure
Auxiliary output (Non-safety output):Protection circuitIncorporated
Current consumption:Large multipurpose indicator lights upEmitter: 120 mA or lessReceiver: 135 mA or less
Current consumption:Large multipurpose indicator lights offEmitter: 70 mA or lessReceiver: 85 mA or less

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top