Service time: Monday to Friday 9:00-18:00
SF4B-A20CA-J05 - SF4B-A20CA-J05 PANASONIC Safety Light Curtain Typ4 (PLe SIL3), Arm Protection, protective height 823,4 mm, P..
In Stock Hot Product

SF4B-A20CA-J05

SF4B-A20CA-J05 PANASONIC Safety Light Curtain Typ4 (PLe SIL3), Arm Protection, protective height 823,4 mm, P..

$0.00USD
3329 in stock
Key Specifications
Item:Specifications
PFHD:2.4 × 10-9(Note) Probability of dangerous failure per hour.
Cable:0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
MTTFD:100 years or more(Note) Mean time to dangerous failure.
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
PFHD2.4 × 10-9(Note) Probability of dangerous failure per hour.
Cable0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
MTTFD100 years or more(Note) Mean time to dangerous failure.
DetailsMin. sensing object ø45 mmø1.772 in(40 mm1.575 inbeam pitch)
ProductCompact Safety Light Curtain[Type4 PLe SIL3]
MaterialEnclosure: Polycarbonate
Beam pitch40 mm1.575 in
Accessories-
Part NumberSF4B-A20CA-J05
Product nameCompact Safety Light Curtain[Type4 PLe SIL3] SF4B-C
ELCA functionIncorporated (reducing mutual interference automatically)
Power voltage24 V DC plus or minus 10 % Ripple P-P 10 % or less
Response timeOFF response: 14 ms or lessON response: 80 to 90 ms
Product NumberSF4B-A20CA-J05
Cable extensionExtension up to total 50 m164.042 ftis possible for both emitter and receiver optional mating cables
Muting functionIncorporated
Operating range0.3 to 7m0.984 to 22.966 ft(Note) The operating range is the possible setting distance between the emitter and the receiver.
Ambient humidity30 to 85 % RH, Storage: 30 to 85 % RH
Emitting elementInfrared LED (Peak emission wavelength: 850 nm0.033 mil)
Pollution degree3
Shock resistance300 m / s2acceleration (30 G approx.) in X, Y and Z directions for three times each
Override functionIncorporated
Protective height823.4 mm32.417 in
Interlock functionIncorporated [Manual reset / Auto reset](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Operating altitude2,000 m6,561.68 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
Optional functionsMuting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing(Note) In case of using optional function, the handy-controller SFB-HC is required.
Ambient illuminanceIncandescent light: 3,500 liter x or less at the light-receiving face
Ambient temperature-10 to +55℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃–3 to +140 ℉
Min. sensing objectø 45 mmø 1.772 inopaque object(Note) In case the blanking function is valid, the operation mode is changed.
No. of beam channels20
Vibration resistance10 to 55 Hz frequency, 0.75 mm0.030 inamplitude in X, Y and Z directions for two hours each
Insulation resistance20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Emission halt functionIncorporated
Muting auxiliary outputNPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m65.617 ftlength cable)
Effective aperture angleplus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
Applicable standards:JapanJIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
CE marking directive complianceMachine Directive, EMC Directive, RoHS Directive
Applicable standards:Europe (EU)EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
Control outputs (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 200 mA• Applied voltage: Same as supply voltage (between the control output and +V)• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3 Ω or less• Maximum sink current: 200 mA• Applied voltage: Same as supply voltage (between the control output and 0 V)• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: : 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3 Ω or less
Applicable standards:North AmericaANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognizedsafety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7
External device monitoring functionIncorporated
Auxiliary output (Non-safety output)PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and +V)• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m65.617 ftlength cable)• Maximum sink current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m65.617 ftlength cable)
Large multi-purpose indicator functionIncorporated
Muting auxiliary output:Operation modeWhen muting auxiliary output: ON
Applicable standards:South Korea (S-Mark)S1-G-35-2005, s2-W-11-2003
Muting auxiliary output:Protection circuitIncorporated
Net weight (Total of emitter and receiver)approx. 910 g
Applicable standards:International standardIEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
Environmental resistance:Degree of protectionIP65 (IEC)
Control outputs (OSSD 1, OSSD 2):Operation modeON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note) During muting, control output will not turn off even if the beams are interrupted.(Note) When the blanking function is enabled, the operating mode will change.
Control outputs(OSSD1, OSSD2):Protection circuitIncorporated
Auxiliary output (Non-safety output):Operation modeOFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Environmental resistance:Dielectric strength voltage1,000 V AC for one min. between all supply terminals connected together and enclosure
Auxiliary output (Non-safety output):Protection circuitIncorporated
Current consumption:Large multipurpose indicator lights upEmitter: 75 mA or lessReceiver: 85 mA or less
Current consumption:Large multipurpose indicator lights offEmitter: 65 mA or lessReceiver: 75 mA or less

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top