Service time: Monday to Friday 9:00-18:00
SF2BA4P - SF2BA4P SF2B-A4-P PANASONIC Safety light curtain, arm type, PNP, 168mm
In Stock Hot Product

SF2BA4P

SF2BA4P SF2B-A4-P PANASONIC Safety light curtain, arm type, PNP, 168mm

$0.00USD
3314 in stock
Key Specifications
Item:Specifications
PFHD:5.90 × 10-9
MTTFD:100 years or more
Details:Min. sensing object ø47 mmø1.850 intype (40 mm1.575 inbeam pitch)
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
PFHD5.90 × 10-9
MTTFD100 years or more
DetailsMin. sensing object ø47 mmø1.850 intype (40 mm1.575 inbeam pitch)
ProductSafety Light Curtain Type 2
MaterialEnclosure: AluminiumUpper and lower edges : Die-cast zine alloyInner case: Polycarbonate / Polyester resinCap: PBT
Beam pitch40 mm1.575 in
Part NumberSF2B-A4-P
Product nameSafety Light Curtain Type 2 SF2B Ver.2
Power voltage24 V DC plus or minus 15 % Ripple P-P 10 % or less
Response timeOFF response: 15 ms or lessON response: 40 to 60 ms
Product NumberSF2B-A4-P
Cable extensionExtension up to total 30.5 m100.066 ftis possible for both emitter and receiver, with optional mating cables.
Operating range0.2 to 13 m0.656 to 42.651 ft(0.2 to 5 m0.656 to 16.404 ftwhen using the SF2B-CB05-B adapter cable)
Ambient humidity30 to 85 % RH, Storage: 30 to 95 % RH
Emitting elementInfrared LED (Peak emission wavelength: 870 nm0.034 mil)
Shock resistance300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each
Connecting methodConnector
Protective height168 mm6.614 in
Ambient illuminanceIncandescent light: 3,500 lx or less at the light-receiving face
Ambient temperature-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 ℃-13 to +158 ℉
Current consumptionEmitter: 35 mA or lessReceiver: 45 mA or less
Min. sensing objectø47 mmø1.850 inopaque object
No. of beam channels4
Vibration resistance10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each
Insulation resistance20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Auxiliary output (Aux)PNP open-collector transistor- Max. source current: 60 mA- Applied voltage: same as supply voltage [between the auxiliary output and +V]- Residual voltage: 2.5 V or less (sink current 60 mA)(when using 30.5 m100.066 ftlength cable)(Note) When using auxiliary output (AUX), the SF2B-CB05-B adapter cable (optional) cannot be used.
Emission halt functionIncorporated
Synchronization methodCable synchronization (optical synchronization when using SF2B-CB05-B)
Effective aperture angleplus or minus 5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / UL 61496-2)]
Applicable standards:JapanJIS B 9704-1/2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL1)
CE marking directive complianceMachinery Directive, EMC Directive, RoHS Directive
Applicable standards:Europe (EU)EN 61496-1 (Type 2), EN 55011
Control outputs (OSSD 1, OSSD 2)PNP open-collector transistor- Max. source current: 200 mA- Applied voltage: same as supply voltage [between the control output (OSSD 1, OSSD 2) and +V]- Residual voltage: 2.5 V or less (sink current 200 mA) (when using 30.5 m100.066 ftlength cable)
Interference prevention functionIncorporated- Series connection: 3 sets max. (Total 128 beam channels). (However, SF2B-Ax allows up to a total of 96 beam channels when two sets are connected, and up to 64 beam channels when three sets are connected). (Note 1)SF2B-Hx and SF2B-Ax can be used together. (Note 2)[When using SF2B-CB05-B (optical synchronization):- Series connection: 3 sets max. (Total 128 beam channels). (However, SF2B-Ax allows up to a total of 96 beam channels when two sets are connected, and up to 64 beam channels when three sets are connected). (Note 1)- Parallel connection: 2 sets max.- Series and parallel mixed connection: Series connection of 3 sets max. and parallel connection of 2 sets max. are simultaneously possible.SF2B-Hx and SF2B-Ax can be used together. (Note 2)](Note 1) The SF2B-H8-x and SF2B-A4-x cannot be connected in series.(Note 2) When making series connection mixing SF2B-Hx and SF2B-Ax, calculate by doubling the number of optical axes only for SF2B-Ax, and make the total number of optical axes fall below 128 axes.(e.g.) When making series connection with SF2B-H36 and SF2B-A44, the total number of optical axes will be 124 axes. The number of optical axes for SF2B-H36 + (number of optical axes for SF2B-A44 × 2) = total number of optical axes. 36 optical axes + (44 optical axes × 2) = 124 optical axes.
Applicable standards:North AmericaUL 61496-1/2 (Type 2), UL 508, UL 1998 (Class 1), CSA C22.2 No.14, CSA C22.2 No.0.8, OSHA 1910.212 (Note), OSHA 1910.217 (C) (Note), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) Not compatible when using the bottom cap cable SF2B-CB05-A.
External device monitoring functionIncorporated
Auxiliary output (Aux):Operation modeWhen using SF2B-CCBx or SF2B-CBx: OFF when OSSD ON, ON when OSSD OFFWhen using SF2B-CB05-A: ON during normal operation, OFF when there is a problem with emitter operation or emission is halted
Weight(Total of emitter and receiver)170 g approx.
Auxiliary output (Aux):Protection circuitIncorporated
Applicable standards:International standardIEC 61496-1/2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL1)
Environmental resistance:Degree of protectionIP65 (IEC) (*IP67 is later than Ver.2)
Control outputs (OSSD 1, OSSD 2):Operation modeON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)
Control outputs(OSSD1, OSSD2):Protection circuitIncorporated
Environmental resistance:Dielectric strength voltage1,000 V AC for one min. between all supply terminals connected together and enclosure

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top