| Parameter | Value |
|---|---|
| • WARNING: Only operate products in perfect condition. Regularly check the products for damage. Immediately take out defective products. Replace the damaged products. The item cannot be repaired. | |
| note | to a max. connection section |
| Data Rate | 100 MBit/s |
| Application | Hybrid |
| Screwing Pg | without |
| Thread type | M40 |
| No. of poles | 15 |
| Product Type | Circular connectors (cable side) |
| Clamping Type | SPEEDCON |
| General notes | Order crimp contacts separately |
| Insertion plan | 6+4+4+XP |
| Gasket material | FKM |
| Nominal voltage | 630 V AC |
| Housing Material | Rotating parts: copper-zinc alloy (CuZn), die-cast parts: zinc (GD-Zn) |
| Degree of pollution | 3 |
| Safety instructions | WARNING: Connectors must not be connected or disconnected under load. Failure to comply with it and use it in accordance with the rules may result in damage to persons and/or property. |
| Overvoltage Category | Iii |
| Direction of rotation | standard |
| Contact Switching Type | female |
| Sizing Impulse Voltage | 6 kV |
| Conductor Outer Diameter | 9 mm ... 14 mm |
| Rated voltage Data contacts | 50 V |
| Rated Voltage Signal Contact | 500 V |
| Sizing CurrentPower Contacts | 70 A |
| Contact Diameter Data Contacts | 0.6 mm |
| Contact DiameterPower Contacts | 3.6 mm |
| Degree of protection (engaged) | IP68/IP69K |
| Wire sectionPower ContactsMax. | 16 mm² |
| Wire sectionPower ContactsMin. | 2.5 mm² |
| Ambient temperature (operating) | -40 °C ... 115 °C |
| Contact DiameterSignal contacts | 1 mm |
| Wire sectionSignal contactsMax. | 1.5 mm² |
| Wire sectionSignal contactsMin. | 0.06 mm² |
| Sizing voltage (II/3) power contact | 850 V DC |
| Voltage sizing (III/3) power contact | 630 V AC |
| Rated current for each signal contact | 8 A |
| Voltage Sizing (III/3) Signal Contact | 500 V |
| Wire cross-section Data contacts max. | 0.25 mm² |
| Wire cross-section Data contacts min. | 0.08 mm² |
| Sizing current for each data contact at 25 °C | 2 A |
Technical specifications and performance data
Installation and operation guide