| Parameter | Value |
|---|---|
| GTIN | 4055626963754 |
| Orderkey | 1099398 |
| (Drawings) | • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). |
| Packing unit | 1 |
| ETIM 5.0 (eCl@ss) | EC002635 |
| ETIM 6.0 (eCl@ss) | EC002061 |
| Custom tariff number | 85389099 |
| Safety note (Drawings) | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
| REACh SVHC (Housing data) | Lead 7439-92-1 |
| eCl@ss 8.0 (Classifications) | 27440102 |
| eCl@ss 9.0 (Classifications) | 27440103 |
| eCl@ss 10.0.1 (Classifications) | 27440102 |
| Coding (Standards and Regulations) | Signal, coding 1 |
| Application (Standards and Regulations) | Power |
| Thread type (Data of the insulating body) | M40 |
| Additional text (Standards and Regulations) | for max. connection cross section |
| Type of contacts (Standards and Regulations) | Pin |
| Type of locking (Data of the insulating body) | for standard and SPEEDCON interlock |
| Housing material (Data of the insulating body) | Turned parts: copper zinc alloy (CuZn), die-cast parts: zinc (GD-Zn) |
| Degree of pollution (Standards and Regulations) | 3 |
| Number of positions (Standards and Regulations) | 9 |
| Rated surge voltage (Standards and Regulations) | 6 kV |
| Overvoltage category (Standards and Regulations) | III |
| Direction of rotation (Standards and Regulations) | Standard |
| Contact connection method (Standards and Regulations) | Crimp connection |
| Rated voltage of power contact (Standards and Regulations) | 630 V AC |
| Rated current for power contacts (Standards and Regulations) | 70 A |
| Contact diameter of power contacts (Standards and Regulations) | 3.6 mm |
| Rated voltage (II/3) power contact (Standards and Regulations) | 850 V DC |
| Contact diameter of signal contacts (Standards and Regulations) | 1 mm |
| Rated voltage (III/3) power contact (Standards and Regulations) | 630 V AC |
| Rated voltage (III/3) signal contact (Standards and Regulations) | 500 V |
| Degree of protection (when plugged in) (Data of the insulating body) | IP68/IP69K |
| Litz wire cross section of power contacts max. (Standards and Regulations) | 16 mm² |
| Litz wire cross section of power contacts min. (Standards and Regulations) | 1 mm² |
| Rated current of each signal contact at 25°C (Standards and Regulations) | 8 A |
| Litz wire cross section of signal contacts max. (Standards and Regulations) | 1.5 mm² |
| Litz wire cross section of signal contacts min. (Standards and Regulations) | 0.06 mm² |
| Dimensional drawingPin version: dimension A = 3.7 mm, socket version: dimension A = 0.05 mm, X = reference position for angle of rotation (Drawings) |
Technical specifications and performance data
Installation and operation guide