| Parameter | Value |
|---|---|
| Step | 1.27 mm |
| Amplitude | 1.5 mm (10 Hz ... 58 Hz) |
| frequency | 10 - 2000 - 10 Hz |
| Shock Type | Semi-sinusoidal |
| Plug Cycles | 500 |
| Sweep speed | 1 octave/min |
| Acceleration | 490 m/s² |
| Product Type | Ready-made IDC plug |
| Test voltage | 500 V AC IEC 60512-4-1:2003 |
| Number of rows | 2 |
| Product Family | FR 1,27-Cabling |
| Contact Coating | 0.9 mm |
| Number of poles | 68 |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Angular Tolerance | ± 5° on longitudinal and transverse axis |
| Contact resistance | 10 mΩ |
| Nominal Current IN | 1.4 A IEC 60512-5-2:2002-02 (at 20 °C 50 poles) |
| Test Specification | IEC 60512-5-2:2002-02 |
| Degree of pollution | 3 |
| Insulating material | LCP |
| Shifting the Center | ± 0.7 mm on longitudinal and transverse axis |
| Contact Resistance R1 | 10 mΩ |
| Contact Resistance R2 | 12 mΩ |
| Duration of the crash | 11 ms |
| Note on documentation | Current documents such as 3D models, product family diagrams, data sheets or packaging diagrams are available in the Download Center. |
| Test duration per axis | 1 h |
| Insulating material group | IIIb |
| CTI according to IEC 60112 | 150 |
| Ambient Temperature (Service) | -55 °C ... 125 °C |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Insulation Resistance Adjacent Poles | ≥ 5 GΩ |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Minimum air gap and creepage line value | 0.32 mm |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
Technical specifications and performance data
Installation and operation guide