Technical Specifications

ParameterValue
GTIN4046356022316
NoteMade to Order (non-returnable)
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1525571
Catalog pagePage 426 (C-2-2017)
Packing unit1 pc
Country of originDE (Germany)
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)Lead 7439-92-1
Custom tariff number85369010
Contact material (General)CuZn
Material, knurls (General)Nickel-plated brass
Sealing material (General)NBR
Coding (Ambient conditions)B - inverse
(Standards and Regulations)≤ 70 °C (cable, drag chain applications)
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Degree of protection (Dimensions)IP67
Test voltage (Ambient conditions)2500 V
Contact carrier material (General)PA 6.6
Contact surface material (General)Ni/Au
Mounting type (Ambient conditions)Front mounting M16 x 1.5 With locking nut
Rated voltage (Ambient conditions)60 V
Status display (Ambient conditions)No
Weight per Piece (excluding packing)318.000 g
Length of cable (Key Commercial Data)5 m
Shielding (Standards and Regulations)Plastic-coated aluminum foil, tinned copper braided shield
Cable type (Standards and Regulations)PROFIBUS
Connection method (Ambient conditions)PROFIBUS
Attenuation (Standards and Regulations)≤ 0.049 dB/m (at 16 MHz)
Wire colors (Standards and Regulations)Red, green
Acceleration (Standards and Regulations)3 m/s²
Cable weight (Standards and Regulations)90 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)2
Rated surge voltage (Ambient conditions)1.5 kV
UL AWM style (Standards and Regulations)21198 (80°C/300 V)
Overall twist (Standards and Regulations)2 cores with 2 fillers to the core
Overvoltage category (Ambient conditions)II
Bending radius (Standards and Regulations)65 mm
Cable capacity (Standards and Regulations)nom. 30 pF/m
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
Wave impedance (Standards and Regulations)150 Ω ±10 % (3 MHz ... 20 MHz)
AWG signal line (Standards and Regulations)24
Cable structure (Standards and Regulations)1x2xAWG24/19
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)4.5 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 85 °C (Plug / socket)
Flame resistance (Standards and Regulations)UL 1581, Sec. 1060 (FT-1)
Material, filler (Standards and Regulations)PP
Other resistance (Standards and Regulations)Low adhesion
Conductor material (Standards and Regulations)Tin-plated Cu litz wires
Conductor resistance (Standards and Regulations)≤ 78.6 Ω/km
Flammability rating according to UL 94 (General)V0
Insertion/withdrawal cycles (Ambient conditions)> 100
Signal type/category (Standards and Regulations)PROFIBUS
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 5 GΩ*km
External sheath, color (Standards and Regulations)violet RAL 4001
Nominal voltage, cable (Standards and Regulations)30 V
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)1500 V (50 Hz, 1 min.)
Conductor cross section (Standards and Regulations)2x 0.25 mm² (Signal line)
Optical shield covering (Standards and Regulations)85 %
Number of bending cycles (Standards and Regulations)4000000
Test voltage Core/Shield (Standards and Regulations)1500 V (50 Hz, 1 min.)
Cable type (abbreviation) (Standards and Regulations)910
External cable diameter D (Standards and Regulations)7.8 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)Foam-Skin PP
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)19x 0.13 mm
Core diameter including insulation (Standards and Regulations)2.55 mm ±0.07 mm
Ambient temperature (storage/transport) (Standards and Regulations)-40 °C ... 80 °C
Smallest bending radius, fixed installation (Standards and Regulations)40 mm
Smallest bending radius, movable installation (Standards and Regulations)65 mm

Product Description

Conect. plug. to be apar. front wall, 2-pole halogen-free, lilac red RAL 4001, shielded, Male connector, straight, M12, coding: B, at free cable end, Front mounting, M16 x 1.5, PROFIBUS, cable length:
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top