Service time: Monday to Friday 9:00-18:00
SACCEC-M12FSD-4CON-M16/2,0-931 - SACCEC-M12FSD-4CON-M16/2,0-931 1528507 PHOENIX CONTACT Bus system flat-type plug
In Stock Hot Product

SACCEC-M12FSD-4CON-M16/2,0-931

SACCEC-M12FSD-4CON-M16/2,0-931 1528507 PHOENIX CONTACT Bus system flat-type plug

$0.00USD
4210 in stock
Key Specifications
GTIN:4046356023436
Note:Made to Order (non-returnable)
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1528507
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356023436
NoteMade to Order (non-returnable)
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1528507
Catalog pagePage 182 (PC-2007)
Packing unit1 pc
Country of originDE (Germany)
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)Lead 7439-92-1
Custom tariff number85444290
Contact material (General)CuZn
Material, knurls (General)Nickel-plated brass
Sealing material (General)NBR
Coding (Ambient conditions)D - data
(Standards and Regulations)-20 °C ... 80 °C (cable, flexible installation)
Degree of protection (Dimensions)IP67
Test voltage (Ambient conditions)2500 V
Contact carrier material (General)PA 6.6
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)60 V
Status display (Ambient conditions)No
Weight per Piece (excluding packing)111.900 g
Length of cable (Key Commercial Data)2 m
Shielding (Standards and Regulations)Aluminum-coated foil, tinned copper braided shield
Cable type (Standards and Regulations)PUR ETHERNET 2x2 FLEX
Attenuation (Standards and Regulations)3.2 dB (with 1 MHz)
Wire colors (Standards and Regulations)white/orange-orange, white/green-green
Cable weight (Standards and Regulations)42 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)according to IEC 60754-1
Number of positions (Ambient conditions)4
UL AWM style (Standards and Regulations)20963 (80°C/30 V)
Overall twist (Standards and Regulations)Two pairs with two fillers to the core
Overvoltage category (Ambient conditions)II
Twisted pairs (Standards and Regulations)2 cores to the pair
Cable capacity (Standards and Regulations)approx. 45 nF/km (at 1 kHz)
Insulation resistance (Ambient conditions)≥ 100 MΩ
Signal runtime (Standards and Regulations)5.3 ns/m
Wave impedance (Standards and Regulations)100 Ω ±5 Ω (at 100 MHz)
AWG signal line (Standards and Regulations)26
Cable structure (Standards and Regulations)2x2xAWG26/7; SF/UTP
Loop resistance (Standards and Regulations)≤ 290.00 Ω/km
Rated current at 40°C (Ambient conditions)4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)according to IEC 60332-1-2
Return loss (RL) (Standards and Regulations)23 dB (at 4 МHz)
Resistance to oil (Standards and Regulations)according to EN 60811-2-1
Conductor material (Standards and Regulations)Bare Cu litz wires
Coupling resistance (Standards and Regulations)≤ 100.00 mΩ/m (at 10 MHz)
Flammability rating according to UL 94 (General)V0
Signal type/category (Standards and Regulations)Ethernet CAT5 (IEC 11801), 100 Mbps
Tensile strength GRP (Standards and Regulations)≤ 80 N
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 500 MΩ*km
External sheath, color (Standards and Regulations)water blue RAL 5021
Nominal voltage, cable (Standards and Regulations)≤ 100 V (Peak value, not for high-power applications)
Outer sheath thickness (Standards and Regulations)1.2 mm
Outer sheath, material (Standards and Regulations)PUR
Test voltage Core/Core (Standards and Regulations)700 V (50 Hz, 1 min.)
Conductor cross section (Standards and Regulations)2x 2x 0.14 mm²
Optical shield covering (Standards and Regulations)70 %
Standards/specifications (Standards and Regulations)Electrical requirements EN 50288-2-2
Test voltage Core/Shield (Standards and Regulations)700 V (50 Hz, 1 min.)
Cable type (abbreviation) (Standards and Regulations)93E
External cable diameter D (Standards and Regulations)6.4 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)Foamed PE
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)7x 0.16 mm
Ambient temperature (installation) (Standards and Regulations)-20 °C ... 80 °C
Core diameter including insulation (Standards and Regulations)0.98 mm
Current carrying capacity of cable (Standards and Regulations)2 A (according to DIN VDE 0891-1)
Near end crosstalk attenuation (NEXT) (Standards and Regulations)65.3 dB (with 1 MHz)
Ambient temperature (storage/transport) (Standards and Regulations)-20 °C ... 80 °C
Minimum bending radius, fixed installation (Standards and Regulations)4 x D
Minimum bending radius, flexible installation (Standards and Regulations)8 x D
Power-summated near end crosstalk attenuation (PSNEXT) (Standards and Regulations)62.3 dB (with 1 MHz)

Product Description

Conect. plug. to be apar. front wall, CAT5 Ethernet (100 MBit/s), Ethernet, 4-pole, PUR, water blue RAL5021, shielded, Connection female, straight, M12, encoding: D, free cable end, Front wall mountin
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top