Service time: Monday to Friday 9:00-18:00
SACCEC-M12FSD-4CON-M16/1,0-931 - SACCEC-M12FSD-4CON-M16/1,0-931 1528497 PHOENIX CONTACT Bus system flat-type plug
In Stock Hot Product

SACCEC-M12FSD-4CON-M16/1,0-931

SACCEC-M12FSD-4CON-M16/1,0-931 1528497 PHOENIX CONTACT Bus system flat-type plug

$0.00USD
4005 in stock
Key Specifications
:• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
Coding:D
Shielded:yes
Cable type:Ethernet flexible CAT5, 2-pair [93E]
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
CodingD
Shieldedyes
Cable typeEthernet flexible CAT5, 2-pair [93E]
ApplicationData
Head designSocket
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
Sensor typeEthernet
Thread typeM12
Cable length1 m
Cable weight42 kg/km
Halogen-freeaccording to IEC 60754-1
Product typeCircular connectors (device side)
Test voltage2500 V
UL AWM Style20963 (80°C/30 V)
Mounting typeFront mounting
Overall twistTwo pairs with two fillers to the core
Seal materialNBR
Twisted pairs2 cores to the pair
Cable capacityapprox. 45 nF/km (at 1 kHz)
Signal runtime5.3 ns/m
Wave impedance100 Ω ±5 Ω (at 100 MHz)
AWG signal line26
Loop resistance≤ 290.00 Ω/km
Article revision17
Contact materialCuZn
Flame resistanceaccording to IEC 60332-1-2
Head thread typeM12
Tensile strength≤ 80 N
Connection methodCable lug connection
Head cable outletstraight
Resistance to oilin accordance with EN 60811-2-1
Conductor materialBare Cu litz wires
Contact resistance≤ 3 mΩ
Nominal current IN4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Nominal voltage UN48 V AC
Notes on operationThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Order information:Lock nut is included in the scope of delivery
Shield attenuation3.2 dB (with 1 MHz)
Single wire, colorwhite/orange-orange, white/green-green
Conductor structure2x2xAWG26/7, SF/UTP
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Degree of pollution3
Dimensional drawing
Number of positions4
Transmission mediumCopper
Degree of protectionIP67
No. of cable outlets1
Overvoltage categoryII
Standard designationM12 connector
Insulation resistance≥ 100 MΩ
External sheath, colorwater blue RAL 5021
Nominal voltage, cable≤ 100 V (Peak value, not for high-power applications)
Outer sheath, materialPUR
Test voltage Core/Core700 V (50 Hz, 1 min.)
Conductor cross section2x 2x 0.14 mm²
Contact connection typeSocket
External cable diameter6.40 mm ±0.2 mm
Optical shield covering70 %
Return attenuation (RL)23 dB (at 4 МHz)
Thickness, outer sheath1.20 mm
Contact carrier materialPA 6.6
Contact surface materialNi/Au
Material wire insulationFoamed PE
Standards/specificationsIEC 61076-2-101
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Wiring standards/regulationsElectrical requirements EN 50288-2-2
Material for screw connectionBrass, nickel-plated
Wire diameter incl. insulation0.98 mm
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line7x 0.16 mm
Ambient temperature (installation)-20 °C ... 80 °C
Current carrying capacity of cable2.00 A (according to DIN VDE 0891-1)
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
Flammability rating according to UL 94V0
Transmission characteristics (category)CAT5 (IEC 11801:2002)
Minimum bending radius, fixed installation4 x D
Smallest bending radius, fixed installation26 mm
Minimum bending radius, flexible installation8 x D
Smallest bending radius, movable installation52 mm
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)

Product Description

Conect. plug. to be apar. front wall, CAT5 Ethernet (100 MBit/s), Ethernet, 4-pole, PUR, water blue RAL5021, shielded, Connection female, straight, M12, encoding: D, free cable end, Front wall mountin
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top