| Parameter | Value |
|---|---|
| • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. | |
| Coding | B |
| Shielded | yes |
| Shielding | Braided copper wires |
| Cable type | INTERBUS |
| Head design | Plug |
| Safety note | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
| Sensor type | INTERBUS |
| Acceleration | 3.2 m/s² |
| Cable length | 5 m |
| Cable weight | 70 kg/km |
| Product type | Circular connectors (device side) |
| Signal speed | 0.66 c |
| Mounting type | Rear mounting |
| Overall twist | 3 pairs to the core |
| Seal material | FKM |
| Twisted pairs | 2 cores to the pair |
| Bending radius | 120 mm |
| Cable capacity | ≤ 60 nF/km (At 800 Hz) |
| Wave impedance | 120 Ω ±20 % (at 64 kHz) |
| AWG signal line | 24 |
| Cable structure | 3 x 2 x 0.22 mm² |
| Loop resistance | ≤ 159.80 Ω/km |
| Traversing path | 10 m |
| Traversing rate | 1.6 m/s |
| Flame resistance | according to VDE 0472, Part 4, test type B |
| Head thread type | M12 |
| Head cable outlet | straight |
| Head locking type | SPEEDCON |
| Conductor material | Bare Cu litz wires |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Notes on operation | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Single wire, color | green-yellow, white-brown, gray-pink |
| Coupling resistance | < 250.00 mΩ/m (at 30 MHz) |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 5 |
| Rated surge voltage | 1.5 kV |
| Transmission medium | Copper |
| Degree of protection | IP67 (When plugged in) |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Signal type/category | INTERBUS |
| Standard designation | M12 connector |
| Insulation resistance | 100 MΩ |
| External sheath, color | may green RAL 6017 |
| Nominal voltage, cable | 250 V (Peak value, not for high-power applications) |
| Outer sheath, material | PUR |
| Test voltage Core/Core | 1500 Vrms |
| Conductor cross section | 3x 2x 0.22 mm² |
| External cable diameter | 8.00 mm |
| Material wire insulation | PE |
| Number of bending cycles | 5000000 |
| Standards/specifications | IEC 61076-2-101 |
| Test voltage Core/Shield | 1000.00 Vrms |
| Cable type (abbreviation) | 900 |
| Cable insulation resistance | ≥ 5 GΩ*km |
| Insertion/withdrawal cycles | > 100 |
| Ambient temperature (operation) | -30 °C ... 70 °C (Cable, flexible installation) |
| Conductor structure signal line | 32x 0.10 mm |
| Near end crosstalk attenuation (NEXT) | ≥ 61 dB (at 772 kHz) |
| Flammability rating according to UL 94 | V0 |
| Minimum bending radius, fixed installation | 7.5 x D |
| Minimum bending radius, flexible installation | 15 x D |
Technical specifications and performance data
Installation and operation guide