| Parameter | Value |
|---|---|
| • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. | |
| Coding | A |
| Shielded | yes |
| Cable type | PUR halogen-free black [PUR] |
| Head design | Pin |
| Safety note | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
| Sensor type | Universal |
| Thread type | M12 |
| Cable length | 2 m |
| Cable weight | 36 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Circular connectors (device side) |
| Test voltage | ≥ 3000 V |
| UL AWM Style | 20549 / 10493 (80°C/300 V) |
| Assembly note | With flat nut |
| Mounting type | Rear mounting M16 x 1.5 With flat nut |
| Overall twist | 4 wires, twisted |
| Seal material | FKM |
| Cable capacity | ≤ 80 pF/m (Conductor-Conductor) |
| Wave impedance | ≥ 62 Ω (f = 10 MHz) |
| AWG signal line | 22 |
| Article revision | 10 |
| Contact material | CuZn |
| Flame resistance | in accordance with UL 758/1581 FT2 |
| Head thread type | M12 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Connection method | Cable connection |
| Head cable outlet | straight |
| Head locking type | SPEEDCON |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Tightening torque | 3 Nm ... 4 Nm (Installation-side) |
| Conductor material | Bare Cu litz wires |
| Contact resistance | ≤ 3 mΩ |
| Nominal current IN | 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed) |
| Nominal voltage UN | 250 V |
| Notes on operation | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Order information: | Lock nut is included in the scope of delivery |
| Single wire, color | brown, white, blue, black |
| Special properties | Flexible cable conduit capable |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 4 |
| Rated surge voltage | 2.5 kV |
| Transmission medium | Copper |
| Degree of protection | IP67 (When plugged in) |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| Thickness, insulation | ≥ 0.21 mm |
| External sheath, color | black-gray RAL 7021 |
| Nominal voltage, cable | ≤ 300 V |
| Outer sheath, material | PUR |
| Conductor cross section | 4x 0.34 mm² (Signal line) |
| Contact connection type | Pin |
| External cable diameter | 4.95 mm ±0.2 mm |
| Optical shield covering | 80 % |
| Thickness, outer sheath | approx. 0.50 mm |
| Contact carrier material | PA 6.6 |
| Contact surface material | Au |
| Material wire insulation | PP |
| Standards/specifications | IEC 61076-2-101 |
| Max. conductor resistance | max. 58 Ω/km (at 20 °C) |
| Insertion/withdrawal cycles | > 100 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 1.27 mm ±0.02 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 42x 0.10 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 10000000, Bending radius: 10 x D, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² |
| Flammability rating according to UL 94 | V0 |
| Minimum bending radius, fixed installation | 5 x D |
| Smallest bending radius, fixed installation | 25 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 50 mm |
Technical specifications and performance data