| Parameter | Value |
|---|---|
| • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. | |
| Coding | A |
| Shielded | yes |
| Cable type | CANopen®/DeviceNet™, PUR, violet [920] |
| Head design | Socket |
| Safety note | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
| Sensor type | CANopen® |
| Thread type | M12 |
| Cable length | 1 m |
| Cable weight | 90 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Circular connectors (device side) |
| UL AWM Style | 21198 (80°C/300 V) |
| Mounting type | Rear mounting |
| Overall twist | 2 pairs around a drain wire in the center to the core |
| Seal material | FKM |
| Twisted pairs | 2 cores to the pair |
| Cable capacity | nom. 40 nF/km (Data cable) |
| Wave impedance | 120 Ω ±10 % (with 1 MHz) |
| AWG signal line | 24 |
| Loop resistance | ≤ 181.80 Ω/km (Data cable) |
| Article revision | 13 |
| Contact material | CuZn |
| Flame resistance | UL 1581, Section 1060 and UL 2556, Section 9.3 (FT1) |
| Head thread type | M12 |
| Other resistance | Low adhesion |
| Connection method | Cable connection |
| Head cable outlet | straight |
| Head locking type | SPEEDCON |
| Tightening torque | 2 Nm ... 3 Nm (Installation-side) |
| Conductor material | Tin-plated Cu litz wires |
| Nominal current IN | 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed) |
| Nominal voltage UN | 48 V AC |
| Notes on operation | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Order information: | Lock nut is included in the scope of delivery |
| Shield attenuation | ≤ 22.9 dB/km (with 1 MHz) |
| Single wire, color | red-black, blue-white |
| Conductor structure | 2xAWG24/19+2xAWG22/19 |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 5 |
| Rated surge voltage | 1.5 kV |
| Transmission medium | Copper |
| Degree of protection | IP67 (When plugged in) |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Standard designation | M12 connector |
| Insulation resistance | 100 MΩ |
| External sheath, color | red lilac RAL 4001 |
| Nominal voltage, cable | ≤ 300 V (Peak value, not for high-power applications) |
| Outer sheath, material | PUR |
| Test voltage Core/Core | 2000 V (50 Hz, 1 min.) |
| Type of pair shielding | Plastic-coated aluminum foil, aluminum side outside |
| Conductor cross section | 2x 0.25 mm² (Data cable) |
| Contact connection type | Socket |
| External cable diameter | 6.70 mm ±0.3 mm |
| Optical shield covering | 80 % |
| Contact carrier material | PA 6.6 |
| Contact surface material | Ni/Au |
| Material wire insulation | Foamed PE (Data cable) |
| Standards/specifications | IEC 61076-2-101 |
| Test voltage Core/Shield | 2000.00 V (50 Hz, 1 min.) |
| Insertion/withdrawal cycles | > 100 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 1.95 mm ±0.05 mm (Data cable) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 19x 0.13 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000000, Bending radius: 70 mm, Bending radius: 10 x D, Traversing path: 4.5 m, Traversing rate: 3 m/s, Acceleration: 3 m/s², Ambient temperature: -20 °C ... 60 °C |
| Flammability rating according to UL 94 | V0 |
| Minimum bending radius, fixed installation | 5 x D |
| Smallest bending radius, fixed installation | 34 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 67 mm |
Technical specifications and performance data
Installation and operation guide